753 results
Honeywell / UDC3500
Equipped with three Form C electro-mechanical relays, the device operates effectively within a power compatibility range of 90 to 250V AC. This controller supports only a single control loop and is capable of handling ambient temperatures between 15 °C and 55 °C with a non-condensing relative humidi
Honeywell / UDC2800
This digital controller allows outputs of either 4 to 20 mA or 0 to 20 mA, alongside a Form C E-M relay rated for 5 Amps, plus Alarm 1 functionality. It operates on 100 to 240V AC power and features a communication interface with one auxiliary output and one or two digital inputs. This device can be
Honeywell / UDC2800
This digital controller accommodates AC power supply ranging from 100 to 240V. It features a communication interface via 10/100M Base-T Ethernet supporting Modbus RTU alongside auxiliary output and digital inputs. Designed for altitudinal installation up to 2000 meters, it operates effectively in re
Honeywell / UDC3500
This digital controller features open collector transistor output but does not have relay outputs. Configurable for single loop control, it supports input options including TC, RTD, mV, and several voltage and current signals. Rated for ambient temperatures between 15 °C and 55 °C, it operates effec
Honeywell / UDC2800
This digital controller features an ambient operating temperature range of 0 °C to 55 °C and allows for installation at elevations up to 2000 meters. The first input channel accepts TC, RTD, mV, and various voltage and current signals from 0-5V to 4-20mA. Its communication interface supports one aux
Honeywell / UDC2800
The DC2800-EE-3L0-200-100-00-0 digital controller operates with an array of inputs, enabling it to process signals from TC, RTD, and mV to various voltage and current types. It includes two Form C electro-mechanical relays, each rated for 5 Amps. Built to maintain functionality within temperatures f
Honeywell / UDC2800
This digital controller provides multiple input options, including thermocouples (TC), resistance temperature detectors (RTD), and various voltage signals. It is certified with CE, UL, CSA, and FM for limit control. The operating conditions allow for an ambient temperature range of 0 °C to 55 °C and
Honeywell / UDC3500
This digital controller supports one input channel capable of handling TC, RTD, and mV signals, in addition to both 0-5V and 1-5V inputs. The device is built for a broad relative humidity range of 10% to 90% (non-condensing) and can endure ambient temperatures from 15 °C to 55 °C. The unit does not