Honeywell / MP918
Operating within a spring range of 3 to 13 psi, this damper actuator weighs 10.5 lbs. It has an air connection that accommodates a barbed fitting suitable for 1/4 inch outer diameter plastic tubing. This unit functions effectively at temperatures spanning from -40°C to 70°C and with relative humidit
Honeywell / MP953
This actuator features an 8-inch diaphragm and is capable of operating under a maximum pressure of 25 psi. It has a stroke size of 8 inches and operates within a spring range of 8 to 12 psi. It accommodates different air connections with two barbed fittings, suitable for either 5/32 inch or 1/4 inch
Honeywell / MP953
This pneumatic coil valve actuator weighs 7.7 lbs and has a spring range between 4 and 11 psi. It connects via two barbed fittings, accommodating both 5/32 in. O.D. and 1/4 in. O.D. plastic tubing. The device performs reliably under temperatures from -18 °C to 60 °C, while maintaining stable operati
Honeywell / 3G SmartVFD
This keypad/interface cable kit has a length of 3 meters and weighs 0.50 lbs. It is designed for compatibility with Honeywell SmartVFD HVAC and 3G SmartVFD Series drives. The cable supports NEMA 1, NEMA 12, and NEMA 3R enclosures, and operates effectively within a temperature range of -10°C to 50°C.
Honeywell / 7800 Series
This programming burner control unit operates within a frequency range of 50 to 60 Hz. It can handle a maximum connected load of 2000 VA. The module establishes a pilot flame in a timeframe of 4 to 10 seconds, while the main flame takes between 10 to 15 seconds. It functions optimally within a tempe
Honeywell / 7800 Series
This burner control features a weight of 1 lb. It establishes the pilot flame within a time frame of 4 to 10 seconds, while the main flame takes 10 to 15 seconds to stabilize. Operating at a frequency between 50 Hz and 60 Hz, this device is compatible with multiple flame amplifiers, including models
Honeywell / 7800 Series
This model supports a pilot flame establishing period ranging from 4 to 10 seconds and a main flame establishing period of 10 to 15 seconds. It operates effectively at a rated voltage of 120 VAC and accommodates a frequency range of 50 to 60 Hz. Operating conditions are suitable in temperatures from
Honeywell / 7800 Series
This burner control unit operates within a frequency range of 50 to 60 Hz. It includes a postpurge interval of 15 seconds and specifies a pilot flame establishment period of 4 to 10 seconds, followed by a main flame establishing period of 10 to 15 seconds. It is designed to function in temperatures
Honeywell / 7800 Series
This burner control module operates effectively at a rated voltage of 120 VAC and supports frequency ranges of 50 to 60 Hz. It can endure environmental temperatures from -40 °C to 60 °C during operation and from -40 °C to 66 °C while stored. The RM7800L1053 is compatible with various flame amplifier
Honeywell / 7800 Series
This control module is part of the 7800 Series, featuring frequency capabilities from 50 Hz to 60 Hz. It is capable of managing a pilot flame establishing period of 4 to 10 seconds and a main flame establishing period of 10 seconds. With a postpurge interval of 15 seconds, it improves overall effici