Honeywell / Modutrol IV
This actuator features a stroke angle range of 90° to 160°. It delivers a torque rating of 150 lb-in, with a breakaway torque of 300 lb-in for initial movement. The actuator can operate with input signals of 135 ohms and supports both 50 Hz and 60 Hz frequencies. It is equipped with two auxiliary sw
Honeywell / 7800 Series
The RM7895E1002 control module can establish pilot flames with timing options of either 15 or 30 seconds. The device features nonvolatile memory and allows for selectable interlocks. It operates within a temperature range from -40°C to 60°C and can withstand humidity levels up to 85% without condens
Honeywell / 7800 Series
This relay control module functions effectively within a frequency range of 50 to 60 Hz and requires a fuse protection rating of 15 Amps. It can operate in harsh conditions, with an operating temperature range between -40°C and 60°C, and can withstand storage temperatures as low as -50°C and as high
Honeywell / 7800 Series
This rectification flame signal amplifier is available in a green color code, with a flame failure response time of either 2 or 3 seconds. It provides an output voltage of 0 to 5.0V DC and is capable of resisting vibrations up to 0.5 G. The device can function at temperatures ranging from -40°C to 6
Honeywell / 7800 Series
This rectification flame amplifier supports a flame failure response time of either 0.8 seconds or 1 second. It operates effectively within a voltage range of 0 to 5.0V DC and features a green-colored protective enclosure. Designed for robust performance, it can withstand exposure to relative humidi
Honeywell / 7800 Series
This flame signal amplifier supports a wide output range of 0 to 5.0V DC and features a dynamic self-checking capability. The device operates effectively within temperature limits of -40°C to 60°C, with a storage temperature range of -40°C to 65°C. Its design includes a green enclosure and offers a
Honeywell / 7800 Series
This relay control module features non-volatile memory, allowing for data retention without power. The device can withstand a minimum operating temperature of -40°C, functioning efficiently up to 60°C. It also has a vibration rating of 0.5 G and supports operation in conditions with relative humidit
Honeywell / 7800 Series
This relay control module features an intermittent pilot type and requires 4 to 10 seconds for pilot flame establishment. It includes dynamic checking for airflow switch validation. Its operation is supported across a temperature range of -40°C to 60°C and can be stored between -40°C and 66°C.
Honeywell / 7800 Series
This relay control module supports on-off primary control applications and is suitable for conditions with a frequency range of 50 to 60 Hz. Its operational temperature tolerance spans from -40 °C to 60 °C, ensuring reliability in extreme environments. It is rated for a relative humidity level of up
Honeywell / 7800 Series
This relay control module is utilized in on-off primary burner control applications, featuring both pre-purge and programmable post-purge capabilities. It has a pilot flame establishing period that can be set to either 4 seconds or 10 seconds. Operating temperatures are robust, spanning from -40°C t