969 results
Honeywell / Other
This valve operates on a voltage of 110/120 V AC and supports both 50 and 60 Hz input frequencies. It features a normally-closed safety shutoff configuration, ensuring secure closing under standby conditions. It draws a current of 0.525 A, and its NPT thread type allows for reliable connections.
Honeywell / Other
The pressure transducer functions accurately within a temperature range of 0 to 40 degrees Celsius for operation and can be stored between 0 and 50 degrees Celsius. It can handle relative humidity levels of up to 80% and is designed for a clean indoor environment without corrosive agents. Installati
Honeywell / Other
This load cell operates with a calibration excitation voltage of 10 Volts DC and features a standard output of 2mV/V. It maintains a bridge resistance of 350 Ω and is made from robust stainless steel, ensuring longevity in demanding environments. The unit has a compensated temperature range between
Honeywell / Micro Switch
Configured as a single pole double throw (SPDT) device, the 51ML1-E1 operates effectively in various environments. This limit switch boasts an operating force of 13.34 N and supports a right-angle body orientation. Additionally, it is suitable for use in explosion-proof environments, reinforcing its
Honeywell / GR Series
This advanced graphic recorder provides a total of 24 analog inputs across three slots, with additional empty slots available for future expansion. It operates within a voltage range of 90-240V AC and has an input frequency of 60 Hz. The device also supports memory expansion through an 8 GB SD card
Honeywell / GR Series
This model offers 8 analog inputs in both Slot A and Slot B, providing ample input options. Additionally, it supports 8 relay inputs or a combination of 2 digital inputs and a mix of 6 fixed outputs or configurable digital I/O options. It operates within a power range of 90-240V AC at a frequency of
Honeywell / DR4500
This circular chart recorder supports two input channels accepting T/C, RTD, Radiamatic, mV, and both 0–5V as well as 4–20mA signals. It includes a control output with SP programming, two alarm outputs, and two digital inputs. The device operates effectively within a temperature range of 0 °C to 55
Honeywell / HercuLine 2002
Designed for a variety of applications, this actuator can rotate up to 150 degrees and has a rated torque of 45 Nm. It operates at a speed of 50 seconds for a full rotation at 60 Hz. The power supply requirements range from 100 to 130 VAC for single-phase operation, and it supports multiple analog i
Honeywell / DR4500
This circular chart recorder is equipped with three input channels that can handle T/C, RTD, Radiamatic, mV, 0–5V, and 4–20mA signals. The operating temperature range extends from 0 °C to 55 °C, ensuring functionality in various environments. Mounting options consist of panel, 2-inch pipe, and surfa
Honeywell / DR4500
This circular chart recorder operates with one input channel, accepting T/C, RTD, Radiamatic signals, as well as mV, 0–5V, and 4–20mA inputs. It includes one control output but lacks auxiliary and external interfaces. The unit features a 12-inch chart for recording and is suitable for a temperature