966 results
Honeywell / SmartVFD HVAC
This variable frequency drive has a continuous output current of 5.6 A. It features a NEMA 1 enclosure type and incorporates communication protocols such as BACnet, Modbus RTU, and N2 (RS485). It includes 6 digital inputs, 2 analog inputs, and 3 relay outputs for flexible control options.
Honeywell / 7800 Series
This burner control features main flame establishment within 10 to 15 seconds and pilot flame establishment in 4 to 10 seconds. It operates across a temperature range from -40 °C to 60 °C. The device uses a rated voltage of 120 VAC and supports frequencies between 50 Hz and 60 Hz.
Honeywell / 7800 Series
This programming burner control is engineered to function within a frequency range of 50 to 60 Hz. It features precise timing protocols for establishing pilot and main flames. The pilot flame establishing period lasts between 4 to 10 seconds, while the main flame establishment takes between 10 to 15
Honeywell / 7800 Series
This burner control operates at a rated voltage of 120 VAC and accommodates frequencies between 50 and 60 Hz. It functions efficiently in environments with operating temperatures from -40 °C to 60 °C, and storage temperatures between -40 °C and 66 °C. The unit also includes a postpurge interval of 1
Honeywell / 7800 Series
This burner control unit effectively manages operational environments with temperatures from -40°C to 60°C and can safely store in temperatures ranging from -40°C to 66°C. It supports high humidity levels up to 85% RH, ensuring reliable functionality. With a power dissipation of up to 10 W, it can a
Honeywell / 7800 Series
With an input voltage frequency range of 50/60 Hz, the unit is built to function effectively within a temperature range from -40°C to 60°C. Designed to endure diverse conditions, it can handle a humidity level of up to 85% RH without condensation. It has a power dissipation limit of 10 W and can sup
Honeywell / 7800 Series
This control unit offers a maximum power dissipation of 10 W and supports a total connected load of up to 2000 VA. It is equipped with fast-blow fusing rated at 15A maximum. The burner control can establish a pilot flame within a span of 4 to 10 seconds. The main flame requires an establishment time
Honeywell / 7800 Series
This burner control unit supports a minimum operating temperature of -40°C, making it ideal for harsh conditions. It can function at temperatures up to 60°C and has a maximum humidity tolerance of 85% RH (non-condensing). With a rated power dissipation of 10 W maximum and a maximum total connected l
Honeywell / V5055
This valve operates effectively within a temperature range from -40°C to 66°C. It is constructed from die-cast aluminum, ensuring durability. The valve can handle a maximum rated pressure of 15 psi and is rated for CSA valve capacity of 10200 cf/hr. Upstream and downstream tapping configurations are
Honeywell / 7800 Series
This burner control module is compatible with a Q7800A2005/Q7800B2003 wiring subbase and is designed for easy plug-in installation. It has a rated maximum of 2000 VA for total connected load and operates within a temperature range of -40°C to 60°C. Built to meet environmental challenges, it performs