966 results
Honeywell / UDC2800
This model supports a primary input channel for various signal types, including TC, RTD, and several voltage standards. It provides a current output rated at either 4 to 20 mA or 0 to 20 mA. The operational temperature range spans from 0 °C to 55 °C, with permissible humidity levels from 5% to 90% (
Honeywell / UDC2800
This universal digital controller provides an output of 4 to 20 mA or 0 to 20 mA current, along with a single alarm relay output. It works with various input configurations including TC, RTD, and mV, as well as 0-5V, 1-5V, and 0-10V signals. Operating conditions allow for a temperature range of 0°C
Honeywell / UDC2800
This universal digital controller features two control outputs. The first output provides a current signal rated at 4 to 20 mA or 0 to 20 mA, while the second includes a 5 Amp Form C electro-mechanical relay with an alarm function. It operates effectively within a temperature range of 0°C to 55°C an
Honeywell / UDC2800
Designed for reliable monitoring, this universal digital controller features two Form C electro-mechanical relay outputs, each rated for 5 Amps. It supports various input types, including TC, RTD, and mV, alongside voltage inputs of 0-5V, 1-5V, and 0-10V. The dynamic controller operates effectively
Honeywell / UDC2800
This universal digital controller boasts two input channels that can accommodate TC, RTD, and millivolt signals, with additional support for 0-5V, 1-5V, and 0-10V signals. Control outputs include a 4-20 mA or 0-20 mA current and a 5 Amp Form C relay output, complete with an alarm function. The opera
Honeywell / UDC2800
This controller features a current output capability rated at either 4 to 20 mA or 0 to 20 mA, providing flexibility in output choices. It includes one alarm relay for signaling conditions. Input options accommodate TC, RTD, and various voltage levels, ensuring compatibility with multiple sensors. O
Honeywell / UDC1200
This controller features a field-selectable universal input type, allowing for flexible input options. It has an input sampling rate of 4 samples per second and offers an impressive 14-bit resolution for analog inputs. Powering this device requires a voltage supply ranging from 90 to 264 VAC and ope
Honeywell / UDC1200
Operating with a power supply voltage accepted in the range of 90 to 264 VAC, this universal limit controller features two electromechanical SPDT relay outputs. It additionally supports a linear DC output for process variable and setpoint retransmission ranging from 4 mA to 20 mA or 0 mA to 20 mA, p
Honeywell / UDC2800
This universal digital controller supports various input types such as thermocouples (TC), resistance temperature detectors (RTD), and voltage signals of 0-5V, 1-5V, and 0-10V. It is rated for installations up to 2000 meters in elevation, and it operates efficiently across temperatures from 0°C to 5
Honeywell / UDC1200
As a universal digital controller, the DC1203-1-1-7-0-1-0-0-0 supports a linear mA input type. It has two relay outputs and one output that provides a 4 to 20 mA linear signal. With no communication options available, this controller is straightforward in implementation. It operates efficiently with