753 results
Honeywell / Micro Switch
With an operating force range between 6 and 12 lbs, this limit switch has a release force set at 4 lbs. It has a current rating of 4.0 amps and can handle up to 28 VDC. Designed for panel mounting, it utilizes wire lead termination and is made from corrosion-resistant steel.
Honeywell / Micro Switch
This limit switch offers a side actuator type and features double-pole, double-throw (DPDT) contacts, facilitating flexible circuit configurations. It is rated for operation in environments classified under NEMA types 1, 3, 4, 4X, 6, 6P, 12, and 13, supporting a broad range of protective requirement
Honeywell / Model 41 Series
This model features an excitation voltage of 10V DC and operates effectively in a temperature range from -54°C to 121°C. It is designed for both tension and compression operations and uses a durable housing made of 17-4PH stainless steel. The load cell accommodates a maximum relative humidity of 80%
Honeywell / Sensepoint XCD
This device operates within a temperature range from 0°C to 40°C and connects to up to 20 remote sensors. It features four DPDT relays capable of 5 amps at 30 volts DC or 250 volts AC. The communication is facilitated via RS-485 Modbus/Vulbus, further enhancing its integration capabilities within la
Honeywell / Sensepoint XCD
This flame detector weighs 1.05 lb and operates at a nominal voltage of 24 VDC with a current rating of 25 mA. Its IP65 rating provides protection against dust and water. The dual-sensor technology employs Ultraviolet/Infrared (UV/IR) sensing, ensuring a detection range of up to 80 ft (25 m). Its co
Honeywell / Searchpoint Optima Plus
With a measurement range extending from 0 to 1000 ppm and a resolution of 1 ppm, this sensor provides detailed detection capability. It is built to operate efficiently within a temperature range of 0°C to 40°C and can function in humidity levels of 0-95% RH without condensation. This unit can be ins
Honeywell / Sensepoint XCD
The SPXCDULNO1M operates with a voltage range of 16-32 VDC and is rated IP66 for dust and water resistance. This detector can monitor oxygen levels from 0-25% volume, utilizing electrochemical sensing technology (Surecell). It includes three relays for alarm and fault signals, and provides output si
Honeywell / 301EM Series
This sensor operates within a temperature span of 0 °C to 40 °C and can withstand humidity levels up to 95% RH without condensation. Its warm-up period is 15 minutes, and it achieves a response time of 60 seconds. With a resolution of 1 ppm and an accuracy of ± 40 ppm at 500 ppm, it ensures reliable
Honeywell / 301EM Series
This sensor measures refrigerant gas within a range of 0 to 1000 ppm, offering a resolution of 1 ppm. The response time for achieving 90% of the final value is 60 seconds, and it requires a 15-minute warm-up time. The sensor operates effectively within temperatures ranging from 0°C to 40°C, alongsid