967 results
Honeywell / Other
This controller is designed for proportional pneumatic control with direct acting action. It has an output pressure span of 3 to 13 psi and accommodates a mainline pressure of 1/2 psi. Operating effectively in ambient temperatures from 5 °C to 55 °C, it is equipped with a combination 5/32 in. air co
Honeywell / Other
This transducer features direct action control and can handle an output pressure range from 3 to 15 psi. It has a maximum operating pressure of 30 psi and consumes 1.7 vA of power. The device operates efficiently in varying humidity levels, supporting a range from 5% to 95% (non-condensing). Its air
Honeywell / Other
This pneumatic controller operates with an input signal ranging from 3 to 15 psi and an output pressure between 3 and 13 psi. It has a minimal airflow consumption of 0.07 scfm and supports an operating pressure of 30 psi. Relative humidity levels for operation can vary from 5% to 95% without condens
Honeywell / Other
The RP7517B1024 transducer ensures an output pressure range from 3 to 15 psi and can withstand maximum operating pressure of 30 psi. Rated for power consumption at 1.7 VA, it features a direct acting mechanism and uses screw terminals or lead wires for electrical connections. With operational temper
Honeywell / Other
This diaphragm gas valve boasts a 2-inch NPT pipe connection and is made from durable cast aluminum. It operates at an input voltage of 120 VAC and a frequency of 60 Hz. The opening and closing timing of this valve is 5 seconds and 2 seconds, respectively, and it operates safely at 1 PSI. A bleed ta
Honeywell / Other
This safety shut-off valve operates within a temperature range of -20 °C to 60 °C and requires manual reset after activation due to overpressure. It is equipped with ANSI flange connections (2 inches) and is suitable for natural gas, LPG, town gas, and biogas. The valve seat is made of durable alumi
Honeywell / Other
Designed for effective operation, this module supports flame monitoring through ionization electrode or UV sensors, with options for intermittent or continuous operation. It accommodates a maximum output contact current of 2 A per output, with a total of 2.5 A combined. Additionally, the unit can be
Honeywell / Other
This device accommodates an input voltage frequency of 50/60 Hz and operates at a current rating of 500 mA. The unit is functional across a temperature range of -20°C to 50°C and can withstand humidity levels from 0 to 95% relative humidity, ensuring reliability in diverse environments. Networking c
Honeywell / Other
This transducer is temperature compensated across a range of 15°C to 71°C and exhibits a high degree of accuracy with ±0.10% full scale measurement. The device also features linearity and hysteresis ratings of ±0.10% and ±0.05% full scale, respectively. Its robust construction includes a case made f
Honeywell / Other
Weighing in at 1.76 lbs, this transmitter supports a humidity range of 0-90% RH without condensation. The housing is finished in black, built from painted steel, ensuring durability. The MIDAS-T-004 operates with a maximum power consumption of approximately 5.0 W (12.95 W with pyrolyzer).