Free UPS Ground on All Parcel Orders!
+1 (919) 205-4392

Search Results

966 results

966 results
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more
Products

51452837-502

51452837-502

Honeywell / UDC3500

This I/O and communications PWA includes support for digital input and current output options. It features RS-422/485 communication compatibility for versatile connections with compatible controllers. Designed to operate within relative humidity levels of 10% to 90% and altitudes up to 1000m, this P

Call
DC2800-E0-1L0-200-200-00-0

DC2800-E0-1L0-200-200-00-0

Honeywell / UDC2800

This device operates under conditions with a minimum temperature rating of 55°C and requires a relative humidity level of at least 90% (non-condensing). It is equipped with an electro-mechanical relay for control output and is designed for installation at altitudes up to 2000 meters.

Call
DC2800-C0-0S0-220-000-00-0

DC2800-C0-0S0-220-000-00-0

Honeywell / UDC2800

This UDC2800 series digital controller offers two input channels supporting thermocouples, resistance temperature detectors (RTDs), millivolt signals, and multiple voltage and current options. The device operates under minimum relative humidity conditions of 90% (non-condensing) and can function at

Call
DC2800-CB-1S0-200-000-00-0

DC2800-CB-1S0-200-000-00-0

Honeywell / UDC2800

This model features a current output rated either at 4-20 mA or 0-20 mA and includes a single alarm relay for enhanced monitoring. Capable of handling inputs such as TC, RTD, and various voltage signals, it effectively measures a wide range of parameters. Operating effectively in temperatures from 0

Call
DC2800-EE-0S0-200-000-00-0

DC2800-EE-0S0-200-000-00-0

Honeywell / UDC2800

This model features two control outputs: one electro-mechanical relay rated at 5 Amps and another Form C relay that also includes Alarm 1, maintaining a consistent 5 Amp rating. It accepts a wide range of inputs that include thermocouples, RTDs, and a variety of voltage and current signals.

Call
DC2800-C0-3S0-100-000-00-0

DC2800-C0-3S0-100-000-00-0

Honeywell / UDC2800

This model supports a primary input channel for various signal types, including TC, RTD, and several voltage standards. It provides a current output rated at either 4 to 20 mA or 0 to 20 mA. The operational temperature range spans from 0 °C to 55 °C, with permissible humidity levels from 5% to 90% (

Call
DC2800-CE-1S0-100-000-00-0

DC2800-CE-1S0-100-000-00-0

Honeywell / UDC2800

This universal digital controller features two control outputs. The first output provides a current signal rated at 4 to 20 mA or 0 to 20 mA, while the second includes a 5 Amp Form C electro-mechanical relay with an alarm function. It operates effectively within a temperature range of 0°C to 55°C an

Call
DC2800-EE-1S0-100-000-00-0

DC2800-EE-1S0-100-000-00-0

Honeywell / UDC2800

Designed for reliable monitoring, this universal digital controller features two Form C electro-mechanical relay outputs, each rated for 5 Amps. It supports various input types, including TC, RTD, and mV, alongside voltage inputs of 0-5V, 1-5V, and 0-10V. The dynamic controller operates effectively

Call
DC2800-CE-0S0-110-000-00-0

DC2800-CE-0S0-110-000-00-0

Honeywell / UDC2800

This universal digital controller boasts two input channels that can accommodate TC, RTD, and millivolt signals, with additional support for 0-5V, 1-5V, and 0-10V signals. Control outputs include a 4-20 mA or 0-20 mA current and a 5 Amp Form C relay output, complete with an alarm function. The opera

Call
DC2800-EE-0L0-200-000-00-0

DC2800-EE-0L0-200-000-00-0

Honeywell / UDC2800

Part of the UDC2800 series, this universal digital controller features two Form C electro-mechanical relays, each rated at 5 Amps. It accepts various signal types, including thermocouple (TC), resistance temperature detectors (RTD), and multiple voltage and current inputs. The operational temperatur

Call
Showing 641-650 of 966 results