This transducer is temperature compensated across a range of 15°C to 71°C and exhibits a high degree of accuracy with ±0.10% full scale measurement. The device also features linearity and hysteresis ratings of ±0.10% and ±0.05% full scale, respectively. Its robust construction includes a case made f
Honeywell / Other
Weighing in at 1.76 lbs, this transmitter supports a humidity range of 0-90% RH without condensation. The housing is finished in black, built from painted steel, ensuring durability. The MIDAS-T-004 operates with a maximum power consumption of approximately 5.0 W (12.95 W with pyrolyzer).
Honeywell / Other
This load cell exhibits a non-linearity accuracy of ±0.1% of full scale and a hysteresis of ±0.08%. It operates effectively within a temperature range of -54°C to 121°C, with temperature compensation guaranteed between 15°C and 71°C. The output signal is non-amplified, providing 3 mV/V ±0.5% FS, sui
Honeywell / GR Series
This advanced graphic recorder provides a total of 24 analog inputs across three slots, with additional empty slots available for future expansion. It operates within a voltage range of 90-240V AC and has an input frequency of 60 Hz. The device also supports memory expansion through an 8 GB SD card
Honeywell / DR4500
This recorder features four input channels capable of reading T/C, RTD, Radiamatic, mV, 0–5V, and 4–20mA signals. The DR4500 series is housed in a NEMA 4X enclosure that includes a door with an acrylic window. Installation is flexible, allowing for panel, 2-inch pipe, or surface mounting.
Honeywell / SmartLine
Designed for flange mounting, this level transmitter has a URL of 400 H2O (1000 mbar) and an LRL of -400 H2O (-1000 mbar). It utilizes a fill fluid made of fluorinated oil CTFE and includes diagnostics features for enhanced operational efficiency. The weight of the device is capped at 32 lbs.
Honeywell / DR4500
Designed to accommodate multiple input types across three channels, this recorder allows for T/C, RTD, Radiamatic, mV, 0–5V, and 4–20mA inputs. It employs a standard pen for recording data, with mounting options available for panel, 2-inch pipe, or surface installations. Operating relative humidity
Honeywell / DR4500
This circular chart recorder is equipped with three input channels that can handle T/C, RTD, Radiamatic, mV, 0–5V, and 4–20mA signals. The operating temperature range extends from 0 °C to 55 °C, ensuring functionality in various environments. Mounting options consist of panel, 2-inch pipe, and surfa
Honeywell / DR4500
This circular chart recorder operates with input channels featuring T/C, RTD, Radiamatic, as well as mV, 0–5V and 4–20mA types. It employs a standard pen for recording and is not equipped with external interfaces or outputs. The device allows for various mounting methods, including panel, 2-inch pip
Honeywell / SmartLine
This gauge pressure transmitter offers a maximum turndown ratio of 100:1, with an upper range limit of 3000 inches of H2O (210 mbar) and a lower range limit of -14.7 inches of H2O (-1 mbar). It comes equipped with a single-ended head and an analog output of 4-20 mA dc, ensuring compatibility with a