969 results
Honeywell / UDC2800
This controller features a current output option rated between 4 and 20 mA or 0 to 20 mA. It includes a 5 Amp Form C electromechanical relay as Control Output 2, capable of functioning as Alarm 1. It accepts a variety of input signals, including TC, RTD, and several voltage and current ranges. Opera
Honeywell / UDC2800
This model is a digital controller featuring multiple inputs including TC, RTD, and mV along with several voltage and current ranges. The device includes an electro-mechanical relay output and supports alarm functions with a 5 Amp capability. Built to function at extremely high relative humidity lev
Honeywell / UDC1200
This universal digital controller operates with a power supply voltage ranging from 90 to 264 volts AC. It features two relay output options and is rated for operation in environments with temperatures between 0 °C and 55 °C. With storage capabilities from -20 °C to 80 °C and a relative humidity tol
Honeywell / UDC3500
This I/O and communications PWA includes support for digital input and current output options. It features RS-422/485 communication compatibility for versatile connections with compatible controllers. Designed to operate within relative humidity levels of 10% to 90% and altitudes up to 1000m, this P
Honeywell / UDC2800
This universal digital controller features one Form C electro-mechanical relay output rated at 5 Amps and one designated alarm relay output. It accepts inputs from thermocouples, RTDs, and millivolt signals, along with voltage ranges of 0-5V, 1-5V, and 0-10V. The operating environment allows for tem
Honeywell / UDC1200
This universal digital controller provides field-selectable universal input types with a sampling rate of 4 samples per second. Its outputs include a configurable linear DC output and an electromechanical SPDT relay. The device operates between 0 °C and +55 °C, with a universal power supply acceptin
Honeywell / UDC2800
This model incorporates an array of input capabilities, accepting thermocouples (TC), resistance temperature devices (RTD), and millivolt signals along with voltage inputs of 0-5V, 1-5V, and 0-10V. With an operational temperature range from 0°C to 55°C, this unit is designed to function reliably in
Honeywell / UDC2800
This controller supports a voltage input from 100 to 240 VAC. It includes one electro-mechanical relay output rated for 5 Amps and provides multiple input types including TC, RTD, and different voltage and current signals. The operating conditions allow for temperatures from 0°C to 55°C and a humidi
Honeywell / UDC2800
This digital controller operates with a single control output rated at either 4 to 20mA or 0 to 20mA. Input capabilities include thermocouples (TC), resistance temperature detectors (RTD), and voltages ranging from 0 to 5V, 1 to 5V, to 0 to 10V. Designed to endure environmental conditions, its speci
Honeywell / UDC2800
Operating efficiently within a temperature range of 0°C to 55°C, this device also maintains performance in relative humidity levels from 5% to 90%, avoiding condensation issues. It is suitable for installation at high altitudes up to 2000 meters and can withstand vibration frequencies of up to 70 Hz