966 results
Honeywell / UDC2800
This controller features two relay outputs: dual Form A relays rated for 2 amps and a Form C E-M relay with a 5-amp capacity. Additionally, the unit accepts diverse input types, including TC, RTD, mV, and current signals ranging from 0-20mA or 4-20mA. It also includes an RS-485 Modbus communication
Honeywell / UDC2800
This digital controller supports power ranging from 100 to 240 VAC. It accommodates input types including thermocouples, RTDs, mV signals, and various voltage and current inputs. The controller operates effectively within a temperature range of 0 °C to 55 °C. Its communication capabilities include a
Honeywell / UDC2800
This controller includes two Form C electro-mechanical relay outputs, each rated at 5 Amps, with the second output also offering an alarm function. It supports multiple input types including TC, RTD, and mV as well as standard voltage and current signals. The device features a 10/100M Base-T Etherne
Honeywell / UDC2800
This digital controller supports input types such as TC, RTD, and mV, as well as voltage inputs of 0-5V, 1-5V, and 0-10V. It is designed with a RS-485 Modbus communication interface and includes two Form C electro-mechanical relay outputs, each rated for 5 Amps. The unit operates efficiently in cond
Honeywell / UDC3500
Configured with a single control loop, this digital controller supports inputs such as TC, RTD, and several voltage and current options. The controller features three relay outputs with a rating of 5 amps each and includes an open-collector transistor output.
Honeywell / UDC2800
This digital controller includes two Form C electro-mechanical relay outputs rated at 5 Amps. The device features a communication interface with one auxiliary output and the option for up to two digital inputs. Relative humidity can range from 5% to 90% (non-condensing), and it operates effectively
Honeywell / UDC2800
This unit operates under ambient temperatures ranging from 0 °C to 55 °C. It can manage multiple input types, including TC, RTD, and various voltage and current signals. It features dual Form C relays with a capacity of 5 amps each, as well as alarm functionality. Designed to comply with CE standard
Honeywell / UDC3500
This digital controller features open collector transistor output but does not have relay outputs. Configurable for single loop control, it supports input options including TC, RTD, mV, and several voltage and current signals. Rated for ambient temperatures between 15 °C and 55 °C, it operates effec
Honeywell / UDC2800
This digital controller features an ambient operating temperature range of 0 °C to 55 °C and allows for installation at elevations up to 2000 meters. The first input channel accepts TC, RTD, mV, and various voltage and current signals from 0-5V to 4-20mA. Its communication interface supports one aux