Free UPS Ground on All Parcel Orders!
+1 (919) 205-4392

Search Results

966 results

966 results
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more
Products

DC2800-EE-0F0-200-100-00-0

DC2800-EE-0F0-200-100-00-0

Honeywell / UDC2800

Operating effectively at a minimum rated temperature of 55 °C, this controller tolerates a relative humidity level of 90% without condensation. It includes one channel for inputs such as TC, RTD, and mV among others while the second input channel is not utilized. The device can function at an instal

Call
DC2800-EE-1L0-100-200-00-0

DC2800-EE-1L0-100-200-00-0

Honeywell / UDC2800

This model integrates multiple input types including TC, RTD, mV, and voltage signals ranging from 0-5V to 0-10 V. It is designed to maintain functionality at a minimum relative humidity of 90% and can be installed at altitudes up to 2000m. The unit incorporates two control outputs, including electr

Call
51452837-502

51452837-502

Honeywell / UDC3500

This I/O and communications PWA includes support for digital input and current output options. It features RS-422/485 communication compatibility for versatile connections with compatible controllers. Designed to operate within relative humidity levels of 10% to 90% and altitudes up to 1000m, this P

Call
DC2800-EE-0F0-100-100-00-0

DC2800-EE-0F0-100-100-00-0

Honeywell / UDC2800

In the UDC2800 series, the DC2800-EE-0F0-100-100-00-0 features various control outputs, including an electro-mechanical relay. With a 5 Amp Form C relay and alarm output, it also supports temperature input through TC, RTD, mV, and voltage signals ranging from 0-5V to 0-10V. This unit is designed for

Call
DC1201-7-1-0-3-1-0-0-0

DC1201-7-1-0-3-1-0-0-0

Honeywell / UDC1200

This controller features a field-selectable universal input type, allowing for flexible input options. It has an input sampling rate of 4 samples per second and offers an impressive 14-bit resolution for analog inputs. Powering this device requires a voltage supply ranging from 90 to 264 VAC and ope

Call
DC1201-7-1-0-2-1-0-0-0

DC1201-7-1-0-2-1-0-0-0

Honeywell / UDC1200

This universal digital controller provides field-selectable universal input types with a sampling rate of 4 samples per second. Its outputs include a configurable linear DC output and an electromechanical SPDT relay. The device operates between 0 °C and +55 °C, with a universal power supply acceptin

Call
DC2800-EE-0L0-100-000-00-0

DC2800-EE-0L0-100-000-00-0

Honeywell / UDC2800

The device features one electro-mechanical relay with a 5 Amp rating and another 5 Amp Form C E-M relay that includes an Alarm 1 function. It accepts a variety of input types including TC, RTD, mV, and voltages of 0-5V, 1-5V, and 0-10V. Operating within a humidity range of 5% to 90% (non-condensing)

Call
DC2800-EE-0L0-100-200-00-0

DC2800-EE-0L0-100-200-00-0

Honeywell / UDC2800

This model incorporates an array of input capabilities, accepting thermocouples (TC), resistance temperature devices (RTD), and millivolt signals along with voltage inputs of 0-5V, 1-5V, and 0-10V. With an operational temperature range from 0°C to 55°C, this unit is designed to function reliably in

Call
DC120L-1-0-0-3-1-0-0-0

DC120L-1-0-0-3-1-0-0-0

Honeywell / UDC1200

Operating with a power supply voltage accepted in the range of 90 to 264 VAC, this universal limit controller features two electromechanical SPDT relay outputs. It additionally supports a linear DC output for process variable and setpoint retransmission ranging from 4 mA to 20 mA or 0 mA to 20 mA, p

Call
DC2800-EE-0S0-100-100-00-0

DC2800-EE-0S0-100-100-00-0

Honeywell / UDC2800

This universal digital controller can operate effectively within a temperature window of 0°C to 55°C. It includes an electro-mechanical relay output and an additional alarm relay output, both rated at 5 Amps. Measurement input capabilities encompass thermocouples, RTDs, and standard voltage levels (

Call
Showing 651-660 of 966 results