966 results
Honeywell / UDC2800
This device operates under conditions with a minimum temperature rating of 55°C and requires a relative humidity level of at least 90% (non-condensing). It is equipped with an electro-mechanical relay for control output and is designed for installation at altitudes up to 2000 meters.
Honeywell / UDC2800
This UDC2800 series digital controller offers two input channels supporting thermocouples, resistance temperature detectors (RTDs), millivolt signals, and multiple voltage and current options. The device operates under minimum relative humidity conditions of 90% (non-condensing) and can function at
Honeywell / UDC2800
This model features a current output rated either at 4-20 mA or 0-20 mA and includes a single alarm relay for enhanced monitoring. Capable of handling inputs such as TC, RTD, and various voltage signals, it effectively measures a wide range of parameters. Operating effectively in temperatures from 0
Honeywell / UDC2800
This model features two control outputs: one electro-mechanical relay rated at 5 Amps and another Form C relay that also includes Alarm 1, maintaining a consistent 5 Amp rating. It accepts a wide range of inputs that include thermocouples, RTDs, and a variety of voltage and current signals.
Honeywell / UDC2800
Part of the UDC2800 series, this universal digital controller features two Form C electro-mechanical relays, each rated at 5 Amps. It accepts various signal types, including thermocouple (TC), resistance temperature detectors (RTD), and multiple voltage and current inputs. The operational temperatur
Honeywell / UDC1200
Operating with a power supply voltage accepted in the range of 90 to 264 VAC, this universal limit controller features two electromechanical SPDT relay outputs. It additionally supports a linear DC output for process variable and setpoint retransmission ranging from 4 mA to 20 mA or 0 mA to 20 mA, p
Honeywell / UDC2800
This universal digital controller can operate effectively within a temperature window of 0°C to 55°C. It includes an electro-mechanical relay output and an additional alarm relay output, both rated at 5 Amps. Measurement input capabilities encompass thermocouples, RTDs, and standard voltage levels (
Honeywell / UDC2800
This device includes a primary input that is compatible with various signals, such as TC, RTD, mV, and multiple voltage and current types. It is rated for use in temperatures from 0°C to 55°C, operates reliably at altitudes up to 2000 meters, and supports humidity levels between 5% and 90%, non-cond
Honeywell / UDC1200
This 1/16 DIN Controller operates with a weight of just 0.46 lbs and features a limit controller input type. It includes a relay output and a 4-20 mA linear DC output. The minimum frequency supported is 50 Hz, while the maximum frequency is 60 Hz. The controller functions effectively within a temper
Honeywell / UDC1200
This 1/16 DIN controller is designed to handle thermocouple inputs and features slots for up to two relay outputs and one 4-20 mA linear DC output. It operates at frequencies between 50 Hz and 60 Hz and consumes 4W of power. It can sustain operating temperatures from 0°C up to 55°C and has a storage