966 results
Honeywell / Micro Switch
With an operating force range between 6 and 12 lbs, this limit switch has a release force set at 4 lbs. It has a current rating of 4.0 amps and can handle up to 28 VDC. Designed for panel mounting, it utilizes wire lead termination and is made from corrosion-resistant steel.
Honeywell / Micro Switch
This limit switch offers a side actuator type and features double-pole, double-throw (DPDT) contacts, facilitating flexible circuit configurations. It is rated for operation in environments classified under NEMA types 1, 3, 4, 4X, 6, 6P, 12, and 13, supporting a broad range of protective requirement
Honeywell / XNX Universal Transmitters
Capable of detecting hydrogen chloride, this universal gas detector transmitter has a standard measurement range of 0 to 10.0 ppm. Constructed with an IP66-rated enclosure (NEMA 4X), it provides excellent resistance to dust and water. The device features an analog output of 4–20 mA and integrates th
Honeywell / Other
This electrode, suitable for immersion, utilizes a preamp connection and includes 12-foot leads with a 6-pin preamp connector. It supports both measuring and reference electrode functions and features a fast-responding automatic temperature sensor. It operates between 0 degrees Celsius and 100 degre
Honeywell / Other
Designed for effective operation, this module supports flame monitoring through ionization electrode or UV sensors, with options for intermittent or continuous operation. It accommodates a maximum output contact current of 2 A per output, with a total of 2.5 A combined. Additionally, the unit can be
Honeywell / DR4500
This circular chart recorder features four input channels that can accept T/C, RTD, Radiamatic, mV signals, as well as 0–5V and 4–20mA inputs. It employs standard pen technology and offers multiple mounting options including panel, 2-inch pipe, and surface configurations.
Honeywell / SmartLine
This unit features a dual-ended head with a weight of up to 32 lbs. It operates with an upper range limit of 400 in H2O (1000 mbar) and a lower range limit of -400 in H2O (-1000 mbar). The construction includes a 316 SS process head and a 316L SS diaphragm. It is filled with Silicone Oil 200 and int
Honeywell / UDC2800
This unit weighs approximately 3 lbs and is equipped with a main output that can be configured for either 4 to 20 mA or 0 to 20 mA current output, alongside one alarm relay. The device supports a communication interface with an auxiliary output and one or two digital input capabilities. Specified fo
Honeywell / UDC3500
This digital controller features a single loop control, providing flexibility with three Form C electro-mechanical relay outputs rated at 5 Amps each. It supports multiple input types, including TC, RTD, and mV, as well as 0-5V, 1-5V, 0-20mA, and 4-20mA. The operating temperature range for this unit
Honeywell / UDC3500
This controller has a weight of 3 pounds and features power compatibility with 24V AC/DC along with one current output. It accommodates two loops of control and has four digital inputs, enabling effective management of control tasks. The unit operates within a temperature range from 15 °C to 55 °C a