Honeywell / V4055
The V4055D1035 gas valve actuator is characterized by an operational temperature range from -40 °C to 66 °C. It indicates position status clearly with a red OPEN and a yellow SHUT indicator light. This actuator is compatible with V5055C and V5097C valves for secure valve overtravel interlocks, and i
Honeywell / UDC3500
This controller has multiple capabilities including three Form C electro-mechanical relay outputs rated at 5 Amps each, alongside additional relay support. The device can manage two control loops and features a real-time clock providing time-stamped data. It can process an array of input types inclu
Honeywell / SmartLine
Configured to operate with a maximum turndown ratio of 400:1, this device efficiently captures pressure variations. Constructed with a plated carbon steel process head and a 316L stainless steel diaphragm, it ensures durability and reliability. It includes a dual-ended head type and has a standard v
Honeywell / UDC3500
Highlighted by its capability to accommodate two control loops with internal cascading, this digital controller also features three Form C E-M relay outputs rated at 5 amps. It integrates with a 10 Base-T Ethernet connection utilizing Modbus RTU protocol and includes four digital inputs for expanded
Honeywell / UDC3500
This controller has a weight of 3 pounds and features power compatibility with 24V AC/DC along with one current output. It accommodates two loops of control and has four digital inputs, enabling effective management of control tasks. The unit operates within a temperature range from 15 °C to 55 °C a
Honeywell / UDC3500
This controller supports two control loops with internal cascading capabilities. It delivers relay outputs with three Form C E-M relays rated for 5 Amps each. The device is equipped for various inputs, including temperature sensors (TC and RTD) and current output options of 4 to 20 mA and 0 to 20 mA
Honeywell / UDC3500
This digital controller features a weight of 3 lbs and includes three Form C E-M relay outputs rated for 5 Amps each. Additionally, it has two outputs consisting of dual Form A 2-Amp relays and accepts diverse input types such as TC, RTD, mV, and multiple current ranges. It operates within a relativ
Honeywell / UDC3500
This controller features multiple input options including TC, RTD, and mV signals, along with standard voltage and current inputs like 0-5V, 1-5V, 0-20mA, and 4-20mA. It incorporates a total of three relay outputs (5 Amps) alongside dual form A relays for heating and cooling processes. Certification
Honeywell / UDC3500
The Honeywell DC3501-CE-3E0C-200-10000-00-0 digital controller features a single control loop and supports various input signals including TC, RTD, mV, and different current and voltage ranges. It has a communication interface that utilizes 10 Base-T Ethernet and Modbus RTU, while providing 4 digita