969 results
Honeywell / DR4500
This standard chart recorder supports input from T/C, RTD, Radiamatic, mV, 0–5V, and 4–20mA, facilitating a broad range of measurements. It includes a single control output with SP programming capabilities. The unit operates effectively in temperatures from 0 °C to 55 °C and features a door with a g
Honeywell / GR Series
This analog input kit operates efficiently between 0 and 40 degrees Celsius and has storage requirements ranging from 0 to 50 degrees Celsius. It is designed to function comfortably within an operating humidity level of up to 80% while not condensing. The kit can be utilized effectively at altitudes
Honeywell / UDC2800
This unit operates under ambient temperatures ranging from 0 °C to 55 °C. It can manage multiple input types, including TC, RTD, and various voltage and current signals. It features dual Form C relays with a capacity of 5 amps each, as well as alarm functionality. Designed to comply with CE standard
Honeywell / UDC3500
Equipped with three Form C electro-mechanical relays, the device operates effectively within a power compatibility range of 90 to 250V AC. This controller supports only a single control loop and is capable of handling ambient temperatures between 15 °C and 55 °C with a non-condensing relative humidi
Honeywell / UDC2800
This digital controller has a weight of 3 lbs and supports outputs of 4 to 20 mA or 0 to 20 mA. Additionally, it features a Form C E-M relay rated for 5 Amps. The unit offers dual input configurations for temperature sensors (TC), RTD, and millivolt signals, as well as standard voltage inputs of 0-5
Honeywell / UDC2800
This digital controller operates within a voltage range of 100 to 240V AC, featuring two Form C relays capable of handling 5 Amps each. The device can function within relative humidity levels of 5% to 90% (non-condensing) and can withstand ambient temperatures from 0 °C to 55 °C, making it suitable
Honeywell / UDC1700
The Honeywell DC170R model is a digital controller with capabilities for remote setpoint input and fuzzy logic processing. It provides a linear output of 4 to 20 mA, but does not include additional output options or a communication interface, and operates within a power supply range of 90 to 264 VAC
Honeywell / UDC2800
This device features dual inputs compatible with TC, RTD, mV, and various voltage and current signal ranges. It includes a 4 to 20mA or 0 to 20mA current output and one alarm relay for effective signaling. Designed for operation in humid conditions, it can withstand a minimum relative humidity of 90
Honeywell / UDC2800
This digital controller is designed for use with various input signals including TC, RTD, and millivolt configurations, as well as voltage and current inputs ranging from 0-5V up to 4-20mA. The device has a rated operating temperature of 55 °C, operates effectively within 90% relative humidity (non-