Honeywell / UDC2800
This digital controller features dual outputs: one is a Form C electro-mechanical relay rated for 5 Amps, while the second output also provides a Form C relay with an alarm feature. The unit supports a wide range of temperature and humidity conditions, thriving in environments from 0 °C to 55 °C and
Honeywell / UDC2800
This digital controller accommodates input signals from thermocouples, resistance temperature detectors (RTD), and millivolt inputs, as well as multiple voltage and current ranges including 0-5V, 1-5V, and 0-10V. It is suitable for installation at altitudes up to 2000 meters, operating efficiently w
Honeywell / UDC2800
This digital controller is designed for use with various input signals including TC, RTD, and millivolt configurations, as well as voltage and current inputs ranging from 0-5V up to 4-20mA. The device has a rated operating temperature of 55 °C, operates effectively within 90% relative humidity (non-
Honeywell / UDC2800
Designed for flexibility, this digital controller accepts various input signals including TC, RTD, and millivolt inputs. It can handle a voltage input of 100 to 240V AC and has an output current rating for control of 4 to 20mA or 0 to 20mA. Environmental conditions can be accommodated with a minimum
Honeywell / UDC2800
This digital controller includes multiple input options, such as TC, RTD, mV, and various voltage and current signals. It features electro-mechanical relay outputs and supports slidewire inputs. Additionally, the controller is rated for a minimum ambient temperature of 55°C and operates effectively
Honeywell / UDC2800
This UDC2800 series digital controller offers two input channels supporting thermocouples, resistance temperature detectors (RTDs), millivolt signals, and multiple voltage and current options. The device operates under minimum relative humidity conditions of 90% (non-condensing) and can function at
Honeywell / UDC2800
This digital controller from the UDC2800 series can handle input signals from thermocouples (TC), RTDs, and mV sources, as well as voltage inputs of 0-5V, 1-5V, and 0-10V. It is rated for a minimum operating temperature of 55°C and a relative humidity level of 90% without condensation. The device is
Honeywell / UDC2800
This digital controller supports a voltage range between 100 and 240V AC, and operates efficiently at a minimum rated temperature of 55°C. The control outputs include an electro-mechanical relay along with a 5 Amp Form C relay that also provides an alarm function. Inputs include thermocouples, RTDs,
Honeywell / UDC2800
This model supports a primary input channel for various signal types, including TC, RTD, and several voltage standards. It provides a current output rated at either 4 to 20 mA or 0 to 20 mA. The operational temperature range spans from 0 °C to 55 °C, with permissible humidity levels from 5% to 90% (
Honeywell / UDC2800
This universal digital controller focuses on delivering reliable performance with an input capacity for thermocouples, RTDs, and millivolt signals, alongside voltage inputs of 0-5V, 1-5V, and 0-10V. It operates efficiently between 0°C to 55°C and manages relative humidity conditions from 5% to 90%.