Free UPS Ground on All Parcel Orders!
+1 (919) 205-4392

Search Results

966 results

966 results
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more
Products

EXH-AR7

EXH-AR7

Honeywell / Micro Switch

With an operating force range between 6 and 12 lbs, this limit switch has a release force set at 4 lbs. It has a current rating of 4.0 amps and can handle up to 28 VDC. Designed for panel mounting, it utilizes wire lead termination and is made from corrosion-resistant steel.

Call
LSXA4L-1A

LSXA4L-1A

Honeywell / Micro Switch

This limit switch offers a side actuator type and features double-pole, double-throw (DPDT) contacts, facilitating flexible circuit configurations. It is rated for operation in environments classified under NEMA types 1, 3, 4, 4X, 6, 6P, 12, and 13, supporting a broad range of protective requirement

Call
XNXXSR1SS

XNXXSR1SS

Honeywell / XNX Universal Transmitters

Capable of detecting hydrogen chloride, this universal gas detector transmitter has a standard measurement range of 0 to 10.0 ppm. Constructed with an IP66-rated enclosure (NEMA 4X), it provides excellent resistance to dust and water. The device features an analog output of 4–20 mA and integrates th

Call
31074387-501

31074387-501

Honeywell / Other

This electrode, suitable for immersion, utilizes a preamp connection and includes 12-foot leads with a 6-pin preamp connector. It supports both measuring and reference electrode functions and features a fast-responding automatic temperature sensor. It operates between 0 degrees Celsius and 100 degre

Call
KS88650354

KS88650354

Honeywell / Other

Designed for effective operation, this module supports flame monitoring through ionization electrode or UV sensors, with options for intermittent or continuous operation. It accommodates a maximum output contact current of 2 A per output, with a total of 2.5 A combined. Additionally, the unit can be

Call
060-J576-07

060-J576-07

Honeywell / Model 41 Series

This pressure transducer supports a minimum operating temperature of 0 degrees Celsius and a maximum of 40 degrees Celsius. It is also designed to function efficiently within a relative humidity of up to 80%, maintaining performance without condensation.

Call
STF724-E1HN4A-A1F-A-AHA-11S-A-00A0-00-0000

STF724-E1HN4A-A1F-A-AHA-11S-A-00A0-00-0000

Honeywell / SmartLine

This unit features a dual-ended head with a weight of up to 32 lbs. It operates with an upper range limit of 400 in H2O (1000 mbar) and a lower range limit of -400 in H2O (-1000 mbar). The construction includes a 316 SS process head and a 316L SS diaphragm. It is filled with Silicone Oil 200 and int

Call
DC2800-CB-1D0-200-000-00-0

DC2800-CB-1D0-200-000-00-0

Honeywell / UDC2800

This unit weighs approximately 3 lbs and is equipped with a main output that can be configured for either 4 to 20 mA or 0 to 20 mA current output, alongside one alarm relay. The device supports a communication interface with an auxiliary output and one or two digital input capabilities. Specified fo

Call
STD820-A1HC4AS-1-A-AH0-11S-B-10A0-0 0-0000

STD820-A1HC4AS-1-A-AH0-11S-B-10A0-0 0-0000

Honeywell / SmartLine

Configured to operate with a maximum turndown ratio of 400:1, this device efficiently captures pressure variations. Constructed with a plated carbon steel process head and a 316L stainless steel diaphragm, it ensures durability and reliability. It includes a dual-ended head type and has a standard v

Call
DC3500-EE-1J0C-111-00000-E0-0

DC3500-EE-1J0C-111-00000-E0-0

Honeywell / UDC3500

This digital controller features a single loop control, providing flexibility with three Form C electro-mechanical relay outputs rated at 5 Amps each. It supports multiple input types, including TC, RTD, and mV, as well as 0-5V, 1-5V, 0-20mA, and 4-20mA. The operating temperature range for this unit

Call
Showing 681-690 of 966 results