966 results
Honeywell / DR4500
This recording device features four input channels capable of handling T/C, RTD, Radiamatic, millivolt, 0-5V, and 4-20mA signals. The recorder has a standard door latch and a gray door with an acrylic window. It can be mounted in various ways, including panel, 2-inch pipe, or surface mounting method
Honeywell / DR4500
This circular chart recorder is equipped with three input channels that can handle T/C, RTD, Radiamatic, mV, 0–5V, and 4–20mA signals. The operating temperature range extends from 0 °C to 55 °C, ensuring functionality in various environments. Mounting options consist of panel, 2-inch pipe, and surfa
Honeywell / DR4500
This standard circular chart recorder has two input channels compatible with T/C, RTD, Radiamatic, mV, 0–5V, and 4–20mA signals. It connects through an RS485 Modbus RTU interface and supports multiple mounting options including panel, 2-inch pipe, and surface. The device features a gray door with an
Honeywell / DR4500
This circular chart recorder operates with input channels featuring T/C, RTD, Radiamatic, as well as mV, 0–5V and 4–20mA types. It employs a standard pen for recording and is not equipped with external interfaces or outputs. The device allows for various mounting methods, including panel, 2-inch pip
Honeywell / UDC3500
This controller has a weight of 3 pounds and features power compatibility with 24V AC/DC along with one current output. It accommodates two loops of control and has four digital inputs, enabling effective management of control tasks. The unit operates within a temperature range from 15 °C to 55 °C a
Honeywell / UDC3500
This controller supports two control loops with internal cascading capabilities. It delivers relay outputs with three Form C E-M relays rated for 5 Amps each. The device is equipped for various inputs, including temperature sensors (TC and RTD) and current output options of 4 to 20 mA and 0 to 20 mA
Honeywell / UDA2182
This analyzer can accommodate pH/ORP inputs on Channel 1 and is rated for an operating temperature range of 0 to 60°C. The unit does not include additional channels for inputs or outputs. It is designed for an installation altitude of up to 2000 meters and comes equipped with a graphical LCD display
Honeywell / HercuLine 2000
This actuator operates on a single-phase power supply ranging from 100 to 130 VAC and has an input frequency of 60 Hz. It employs a 3-wire drive system for upward and downward movement, facilitating user-friendly analog input signals. The actuator also provides two 1000-ohm analog output signals acr
Honeywell / UDC3500
This digital controller supports multiple input types including thermocouples (TC), resistance temperature detectors (RTD), and milliVolt (mV) configurations as well as various voltage and current signals. It is certified to CE standards and operates efficiently within a range of conditions.
Honeywell / UDC2800
This model integrates two Form C electro-mechanical relay outputs, each rated for 5 Amps. It supports inputs from thermocouples, RTDs, and various voltage and current signals. The controller is designed for ambient temperatures ranging from 0 to 55 °C and can be installed at altitudes up to 2000 met