DC3501-EE-1L2C-322-1T000-E0-0

DC3501-EE-1L2C-322-1T000-E0-0

Honeywell / UDC3500

This controller has multiple capabilities including three Form C electro-mechanical relay outputs rated at 5 Amps each, alongside additional relay support. The device can manage two control loops and features a real-time clock providing time-stamped data. It can process an array of input types inclu

Call
DC3501-CE-3E2C-210-10000-00-0

DC3501-CE-3E2C-210-10000-00-0

Honeywell / UDC3500

This controller supports two control loops with internal cascading capabilities. It delivers relay outputs with three Form C E-M relays rated for 5 Amps each. The device is equipped for various inputs, including temperature sensors (TC and RTD) and current output options of 4 to 20 mA and 0 to 20 mA

Call
UDA2182-PH1-NN2-NN-N-0E00-EE-000

UDA2182-PH1-NN2-NN-N-0E00-EE-000

Honeywell / UDA2182

This analyzer can accommodate pH/ORP inputs on Channel 1 and is rated for an operating temperature range of 0 to 60°C. The unit does not include additional channels for inputs or outputs. It is designed for an installation altitude of up to 2000 meters and comes equipped with a graphical LCD display

Call
DC3500-RE-3000-214-00000-00-0

DC3500-RE-3000-214-00000-00-0

Honeywell / UDC3500

This digital controller features a weight of 3 lbs and includes three Form C E-M relay outputs rated for 5 Amps each. Additionally, it has two outputs consisting of dual Form A 2-Amp relays and accepts diverse input types such as TC, RTD, mV, and multiple current ranges. It operates within a relativ

Call
DC3500-TE-1000-210-00000-E0-0

DC3500-TE-1000-210-00000-E0-0

Honeywell / UDC3500

This digital controller processes multiple input types across two inputs including TC, RTD, and different voltage and current signals. It is powered by 90 to 264V AC, features three Form C E-M relays, and maintains operation in relative humidity between 10% and 90%, non-condensing. The device is des

Call
DC2800-CE-3F0-220-000-00-0

DC2800-CE-3F0-220-000-00-0

Honeywell / UDC2800

This digital controller supports multiple input types including TC, RTD, mV, and other voltage and current signals. It features outputs capable of 4 to 20 mA or 0 to 20 mA. The device is also equipped with a Form C E-M relay rated for 5 amps and an alarm functionality. The communication interface in

Call
DC2800-EE-2F0-240-000-00-0

DC2800-EE-2F0-240-000-00-0

Honeywell / UDC2800

This model integrates two Form C electro-mechanical relay outputs, each rated for 5 Amps. It supports inputs from thermocouples, RTDs, and various voltage and current signals. The controller is designed for ambient temperatures ranging from 0 to 55 °C and can be installed at altitudes up to 2000 met

Call
DC2800-RE-2S0-240-100-00-0

DC2800-RE-2S0-240-100-00-0

Honeywell / UDC2800

This controller features two relay outputs: dual Form A relays rated for 2 amps and a Form C E-M relay with a 5-amp capacity. Additionally, the unit accepts diverse input types, including TC, RTD, mV, and current signals ranging from 0-20mA or 4-20mA. It also includes an RS-485 Modbus communication

Call
DC2800-CE-2S0-220-100-00-0

DC2800-CE-2S0-220-100-00-0

Honeywell / UDC2800

The UDC2800 series features two configurable inputs, accommodating a range of signals such as 0-5V, 1-5V, and 4-20mA. It operates within a 100 to 240 VAC power range and is designed with an RS-485 Modbus communication interface for easy integration. The controller can function in temperatures rangin

Call
DC2800-EE-3S0-240-100-00-0

DC2800-EE-3S0-240-100-00-0

Honeywell / UDC2800

This controller includes two Form C electro-mechanical relay outputs, each rated at 5 Amps, with the second output also offering an alarm function. It supports multiple input types including TC, RTD, and mV as well as standard voltage and current signals. The device features a 10/100M Base-T Etherne

Call
Showing 691-700 of 753 results