969 results
Honeywell / UDC2800
The DC2800-EE-3L0-200-100-00-0 digital controller operates with an array of inputs, enabling it to process signals from TC, RTD, and mV to various voltage and current types. It includes two Form C electro-mechanical relays, each rated for 5 Amps. Built to maintain functionality within temperatures f
Honeywell / UDC2800
This device features dual inputs compatible with TC, RTD, mV, and various voltage and current signal ranges. It includes a 4 to 20mA or 0 to 20mA current output and one alarm relay for effective signaling. Designed for operation in humid conditions, it can withstand a minimum relative humidity of 90
Honeywell / UDC2800
This digital controller is designed for use with various input signals including TC, RTD, and millivolt configurations, as well as voltage and current inputs ranging from 0-5V up to 4-20mA. The device has a rated operating temperature of 55 °C, operates effectively within 90% relative humidity (non-
Honeywell / UDC2800
This digital controller supports a wide array of input types, including TC, RTD, and mV signals, along with voltage options like 0-5V, 1-5V, and 0-10V. Featuring an electro-mechanical relay output rated at 5 Amps, it includes an additional control output for an alarm function. The device operates ef
Honeywell / UDC1200
The DC1201-7-1-1-0-1-0-0-0 model is engineered for loop control and operates with an AC power supply ranging from 90 to 264V. Without a communication option, it remains straightforward in functionality. The weight of this digital controller is 0.46 pounds, suitable for a variety of settings, while i
Honeywell / UDC1200
This unit features three relay outputs for enhanced control capabilities. It operates within a voltage range of 90 to 264 VAC and is rated for frequencies of 50 to 60 Hz. With an operating temperature range from 0°C to 55°C and a storage temperature range from -20°C to 80°C, it is suited for various
Honeywell / UDC1200
This 1/16 DIN controller is engineered to accept 3-wire RTD or DC mV inputs. It features an option slot for a relay output, while another slot allows for a 4-20 mA linear DC output. The device is rated for power compatibility from 90 to 264 VAC and supports operating frequencies of 50 to 60 Hz. Desi
Honeywell / UDC1200
This model operates within a power range of 90 to 264 VAC and has a weight of 0.46 lbs. It features an operating temperature range from 0°C to 55°C and a storage range from -20°C to 80°C. Additionally, it can handle relative humidity levels of 20% to 95%, non-condensing, and can be installed at alti
Honeywell / UDC1200
This 1/16 DIN controller is designed to operate with a power supply ranging from 90 to 264 VAC. It accepts input frequencies between 50 Hz and 60 Hz. The device maintains functionality across an operating temperature range of 0°C to 55°C and has a storage temperature capacity reaching -20°C to 80°C.
Honeywell / MP953