753 results
Honeywell / Micro Switch
This cable pull switch features a contact configuration consisting of one normally open (NO) and one normally closed (NC) direct-acting contact. The actuator includes a blue turn-to-reset knob, and the housing is constructed from die-cast zinc, providing durability. It offers a span length of up to
Honeywell / Micro Switch
With an operating force range between 6 and 12 lbs, this limit switch has a release force set at 4 lbs. It has a current rating of 4.0 amps and can handle up to 28 VDC. Designed for panel mounting, it utilizes wire lead termination and is made from corrosion-resistant steel.
Honeywell / Micro Switch
This limit switch offers a side actuator type and features double-pole, double-throw (DPDT) contacts, facilitating flexible circuit configurations. It is rated for operation in environments classified under NEMA types 1, 3, 4, 4X, 6, 6P, 12, and 13, supporting a broad range of protective requirement
Honeywell / 301EM Series
This sensor operates within a temperature span of 0 °C to 40 °C and can withstand humidity levels up to 95% RH without condensation. Its warm-up period is 15 minutes, and it achieves a response time of 60 seconds. With a resolution of 1 ppm and an accuracy of ± 40 ppm at 500 ppm, it ensures reliable
Honeywell / XNX Universal Transmitters
This electrochemical sensor features a housing made from 316 stainless steel, ensuring durability in various environments. It operates efficiently between 90 to 110 kPa and has a response time of 15 seconds. An IP66 rating indicates solid protection against dust and water, while a NEMA 4X enclosure
Honeywell / Sensepoint XCD
This module is designed to function efficiently across a wide operating temperature range from -40°C to 65°C. It features an IP66 rating, ensuring protection against dust and water ingress. The module includes three programmable relay outputs and communicates via an RS-485 Modbus RTU interface.
Honeywell / XNX Universal Transmitters
Capable of detecting hydrogen chloride, this universal gas detector transmitter has a standard measurement range of 0 to 10.0 ppm. Constructed with an IP66-rated enclosure (NEMA 4X), it provides excellent resistance to dust and water. The device features an analog output of 4–20 mA and integrates th
Honeywell / DR4500
This circular chart recorder operates with input channels featuring T/C, RTD, Radiamatic, as well as mV, 0–5V and 4–20mA types. It employs a standard pen for recording and is not equipped with external interfaces or outputs. The device allows for various mounting methods, including panel, 2-inch pip
Honeywell / UDC3500
This controller supports two control loops with internal cascading capabilities. It delivers relay outputs with three Form C E-M relays rated for 5 Amps each. The device is equipped for various inputs, including temperature sensors (TC and RTD) and current output options of 4 to 20 mA and 0 to 20 mA
Honeywell / UDA2182
This analyzer can accommodate pH/ORP inputs on Channel 1 and is rated for an operating temperature range of 0 to 60°C. The unit does not include additional channels for inputs or outputs. It is designed for an installation altitude of up to 2000 meters and comes equipped with a graphical LCD display