DC3500-T0-0000-200-00000-E0-0

DC3500-T0-0000-200-00000-E0-0

Honeywell / UDC3500

This digital controller features open collector transistor output but does not have relay outputs. Configurable for single loop control, it supports input options including TC, RTD, mV, and several voltage and current signals. Rated for ambient temperatures between 15 °C and 55 °C, it operates effec

Call
DC2800-EE-1L0-200-100-0C-0

DC2800-EE-1L0-200-100-0C-0

Honeywell / UDC2800

This digital controller features an ambient operating temperature range of 0 °C to 55 °C and allows for installation at elevations up to 2000 meters. The first input channel accepts TC, RTD, mV, and various voltage and current signals from 0-5V to 4-20mA. Its communication interface supports one aux

Call
DC2800-EE-2S0-200-100-00-0

DC2800-EE-2S0-200-100-00-0

Honeywell / UDC2800

This digital controller accepts multiple input types including TC, RTD, mV, and different voltage and current signals. It features a Form C electro-mechanical relay for outputs and is certified for compliance with CE, UL, and CSA standards. Its operating temperature range spans from 0 °C to 55 °C, a

Call
DC2800-EB-3L0-100-100-00-0

DC2800-EB-3L0-100-100-00-0

Honeywell / UDC2800

This digital controller accepts a variety of inputs, including TC, RTD, mV, and voltage signals ranging from 0-5V to 0-10V. It is designed for operation in conditions with a minimum rated temperature of 55 °C and relative humidity of 90% (non-condensing). Evaluated for an altitude of up to 2000 m, i

Call
DC2800-EE-3L0-100-000-00-0

DC2800-EE-3L0-100-000-00-0

Honeywell / UDC2800

This device weighs 3 lbs and utilizes electro-mechanical relays for control outputs, including a 5 Amp Form C E-M relay. The first input accommodates TC, RTD, and millivolt signals, in addition to voltage inputs of 0-5V, 1-5V, and 0-10V. It is designed for high operational reliability, functioning o

Call
DC2800-EE-0L0-200-200-00-0

DC2800-EE-0L0-200-200-00-0

Honeywell / UDC2800

This model is a digital controller featuring multiple inputs including TC, RTD, and mV along with several voltage and current ranges. The device includes an electro-mechanical relay output and supports alarm functions with a 5 Amp capability. Built to function at extremely high relative humidity lev

Call
DC2800-EE-0L0-100-100-00-0

DC2800-EE-0L0-100-100-00-0

Honeywell / UDC2800

This digital controller supports a broad voltage rating between 100 to 240V AC and is equipped with two control outputs that include an electro-mechanical relay and a Form C relay rated for 5 amps. It accommodates a variety of input signals, specifically TC, RTD, mV, and voltage configurations of 0-

Call
DC2800-EE-1L0-200-000-00-0

DC2800-EE-1L0-200-000-00-0

Honeywell / UDC2800

This digital controller is designed for use with various input signals including TC, RTD, and millivolt configurations, as well as voltage and current inputs ranging from 0-5V up to 4-20mA. The device has a rated operating temperature of 55 °C, operates effectively within 90% relative humidity (non-

Call
DC2800-E0-3L0-100-100-00-0

DC2800-E0-3L0-100-100-00-0

Honeywell / UDC2800

Incorporating an input for various types of sensors including thermocouples (TC), resistance temperature devices (RTD), and voltage signals (0-5V, 1-5V, and 0-10V), this device is engineered to meet diverse operational needs. The unit is constructed to function effectively at a minimum temperature o

Call
DC2800-EE-0F0-200-100-00-0

DC2800-EE-0F0-200-100-00-0

Honeywell / UDC2800

Operating effectively at a minimum rated temperature of 55 °C, this controller tolerates a relative humidity level of 90% without condensation. It includes one channel for inputs such as TC, RTD, and mV among others while the second input channel is not utilized. The device can function at an instal

Call
Showing 731-740 of 966 results