Honeywell / Other
This pneumatic controller operates with an input signal ranging from 3 to 15 psi and an output pressure between 3 and 13 psi. It has a minimal airflow consumption of 0.07 scfm and supports an operating pressure of 30 psi. Relative humidity levels for operation can vary from 5% to 95% without condens
Honeywell / Other
The RP920A1025 model features an input signal range of 3 to 15 psi and can output between 3 and 13 psi. Its design accommodates a minimum air pressure of 15 psi and a maximum of 30 psi, ensuring reliability in pneumatic systems. The controller operates effectively in temperatures between 5°C and 55°
Honeywell / Other
This combined viewing head and signal processor weighs 6.1 lbs and features a heavy-duty aluminum housing. It mounts using a 1” NPT female connection and offers a flame failure response time of 1 to 3 seconds. With a conduit connection of 3/4” NPT, it provides reliable integration into various syste
Honeywell / Other
This component features an IP 65 enclosure rating, providing robust protection against dust and water. The assembly weighs 8.36 lbs and includes a 2-inch NPT internal threaded pipe connection, facilitating seamless integration into gas systems. The valve operates with a size 2 configuration, utilizi
Honeywell / Other
This adapter features a USB Type A plug and has a lightweight design at 0.2 lbs. Its optical interface supports a baud rate of 2400. The cable extends 3 meters in length, allowing for some flexibility in setup. This device operates effectively between temperatures of -20 °C to 60 °C and can be store
Honeywell / Other
This valve operates within a frequency range of 50/60 Hz and has an IP65 enclosure rating for protection against dust and water ingress. It supports a maximum inlet pressure of 500 mbar (7 psig) and operates effectively in temperatures from -20 °C to 60 °C. This device includes a proof of closure sw
Honeywell / Other
This controller maintains an operating temperature range from -20°C to 50°C and can handle ambient humidity levels from 0% to 95% RH without condensation. It can support three RS-485 channels and connect up to 96 transmitter inputs. Communication options include Modbus RS-485 and optional BACnet/IP,
Honeywell / Other
This device accommodates an input voltage frequency of 50/60 Hz and operates at a current rating of 500 mA. The unit is functional across a temperature range of -20°C to 50°C and can withstand humidity levels from 0 to 95% relative humidity, ensuring reliability in diverse environments. Networking c
Honeywell / Other
This transducer is temperature compensated across a range of 15°C to 71°C and exhibits a high degree of accuracy with ±0.10% full scale measurement. The device also features linearity and hysteresis ratings of ±0.10% and ±0.05% full scale, respectively. Its robust construction includes a case made f