969 results
Honeywell / UDC2800
This digital controller features a control output of 4 to 20mA or 0 to 20mA, ensuring compatibility with various systems. It accepts inputs including thermocouples (TC), resistance temperature detectors (RTD), and millivolt signals, along with voltage inputs of 0-5V, 1-5V, and 0-10V. Operating in en
Honeywell / UDC2800
Incorporating a single input for TC, RTD, and other signals, the UDC2800 can manage mV as well as voltage input options of 0-5V, 1-5V, and 0-10V. Operating between temperatures of 0°C and 55°C, it also tolerates relative humidity levels from 5% to 90% (non-condensing). With a maximum installation al
Honeywell / UDC1200
This controller works within an input range of 90 to 264 volts AC and operates at frequencies between 50 and 60 Hz. Its operating temperature spans from 0°C to 55°C while the storage temperature allows for a range of -20°C to 80°C. The unit is rated for relative humidity between 20% and 95% non-cond
Honeywell / UDC2800
Operating efficiently within a temperature range of 0°C to 55°C, this device also maintains performance in relative humidity levels from 5% to 90%, avoiding condensation issues. It is suitable for installation at high altitudes up to 2000 meters and can withstand vibration frequencies of up to 70 Hz
Honeywell / VGF Series
This flanged globe valve operates with a two-way body pattern and is constructed from durable cast iron with stainless steel trim components. It supports a closing pressure of up to 34 psi and operates within a temperature range from -7 °C to 121 °C. The valve utilizes a direct-acting mechanism and
Honeywell / 3G SmartVFD
This variable frequency drive is capable of operating with a minimum frequency of 50 Hz and a maximum frequency of 60 Hz. It has a substantial rated output current of 16.5 A and features both analog and digital I/O options, including 2 analog inputs, 2 analog outputs, 6 digital inputs, and 2 digital
Honeywell / MP953
This positive positioner kit operates within a temperature range from 0°F to 140°F and ensures optimal operation with a maximum relative humidity of 80% (non-condensing). It can be used at altitudes not exceeding 1000 meters and is designed to meet specific operating standards for pneumatic valve co
Honeywell / 7800 Series
This relay control module features an intermittent pilot type and requires 4 to 10 seconds for pilot flame establishment. It includes dynamic checking for airflow switch validation. Its operation is supported across a temperature range of -40°C to 60°C and can be stored between -40°C and 66°C.
Honeywell / Other
This device features a single control loop and is equipped with an output relay in its first slot. The communications capability includes Ethernet integration, facilitating easy networking. It operates effectively within a temperature range of 0 °C to 55 °C and can be installed at altitudes up to 20
Honeywell / Other
This glass pH electrode supports a wide variety of applications for both measuring and reference roles. It is adaptable to any mounting position and functions within a temperature range of 0 to 100 degrees Celsius. Direct connections are available for UDA2182, APT2000, and APT4000 devices, and the m