Free UPS Ground on All Parcel Orders!
+1 (919) 205-4392

Search Results

966 results

966 results
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more
Products

DC2800-EE-0S0-240-000-00-0

DC2800-EE-0S0-240-000-00-0

Honeywell / UDC2800

This digital controller includes multiple input options, such as TC, RTD, mV, and various voltage and current signals. It features electro-mechanical relay outputs and supports slidewire inputs. Additionally, the controller is rated for a minimum ambient temperature of 55°C and operates effectively

Call
DC2800-EE-1L0-100-200-00-0

DC2800-EE-1L0-100-200-00-0

Honeywell / UDC2800

This model integrates multiple input types including TC, RTD, mV, and voltage signals ranging from 0-5V to 0-10 V. It is designed to maintain functionality at a minimum relative humidity of 90% and can be installed at altitudes up to 2000m. The unit incorporates two control outputs, including electr

Call
DC2800-CE-1S0-200-000-00-0

DC2800-CE-1S0-200-000-00-0

Honeywell / UDC2800

With a current output of 4 to 20mA or 0 to 20mA, the device provides flexible control options. It also includes a Form C electromechanical relay rated at 5 amps, which can be used for alarm functions. The primary input accommodates a variety of signal types such as TC, RTD, mV, and voltage inputs fr

Call
DC2800-EE-1S0-200-000-00-0

DC2800-EE-1S0-200-000-00-0

Honeywell / UDC2800

Weighing in at 3 lbs, the UDC2800 model functions within an input voltage range of 100 to 240V AC. It provides control outputs including an electro-mechanical relay and a 5 Amp Form C relay, suitable for diverse control tasks. The considerable input flexibility covers TC, RTD, mV, and current signal

Call
DC2800-CB-1S0-200-100-00-0

DC2800-CB-1S0-200-100-00-0

Honeywell / UDC2800

This digital controller includes one current output that can be set to either 4 to 20 mA or 0 to 20 mA, along with one alarm relay output. It supports multiple input types including thermocouples (TC), resistance temperature devices (RTD), and millivolt signals, as well as voltage and current inputs

Call
DC2800-E0-1L0-200-200-00-0

DC2800-E0-1L0-200-200-00-0

Honeywell / UDC2800

This device operates under conditions with a minimum temperature rating of 55°C and requires a relative humidity level of at least 90% (non-condensing). It is equipped with an electro-mechanical relay for control output and is designed for installation at altitudes up to 2000 meters.

Call
DC2800-EE-0F0-100-100-00-0

DC2800-EE-0F0-100-100-00-0

Honeywell / UDC2800

In the UDC2800 series, the DC2800-EE-0F0-100-100-00-0 features various control outputs, including an electro-mechanical relay. With a 5 Amp Form C relay and alarm output, it also supports temperature input through TC, RTD, mV, and voltage signals ranging from 0-5V to 0-10V. This unit is designed for

Call
DC2800-EE-0S0-200-000-00-0

DC2800-EE-0S0-200-000-00-0

Honeywell / UDC2800

This model features two control outputs: one electro-mechanical relay rated at 5 Amps and another Form C relay that also includes Alarm 1, maintaining a consistent 5 Amp rating. It accepts a wide range of inputs that include thermocouples, RTDs, and a variety of voltage and current signals.

Call
DC2800-CB-0F0-200-000-00-0

DC2800-CB-0F0-200-000-00-0

Honeywell / UDC2800

This controller offers a current output that can be set to either 4 to 20 mA or 0 to 20 mA, alongside a single alarm relay. It accepts a variety of input signals, including TC, RTD, mV, and voltage options such as 0-5V and 1-5V. Designed to operate in temperatures from 0°C to 55°C, it functions with

Call
DC2800-EB-0L0-100-200-00-0

DC2800-EB-0L0-100-200-00-0

Honeywell / UDC2800

This universal digital controller features one Form C electro-mechanical relay output rated at 5 Amps and one designated alarm relay output. It accepts inputs from thermocouples, RTDs, and millivolt signals, along with voltage ranges of 0-5V, 1-5V, and 0-10V. The operating environment allows for tem

Call
Showing 741-750 of 966 results