Honeywell / DR4500
This recorder features four input channels capable of reading T/C, RTD, Radiamatic, mV, 0–5V, and 4–20mA signals. The DR4500 series is housed in a NEMA 4X enclosure that includes a door with an acrylic window. Installation is flexible, allowing for panel, 2-inch pipe, or surface mounting.
Honeywell / DR4500
Designed to accommodate multiple input types across three channels, this recorder allows for T/C, RTD, Radiamatic, mV, 0–5V, and 4–20mA inputs. It employs a standard pen for recording data, with mounting options available for panel, 2-inch pipe, or surface installations. Operating relative humidity
Honeywell / DR4500
This recording device features four input channels capable of handling T/C, RTD, Radiamatic, millivolt, 0-5V, and 4-20mA signals. The recorder has a standard door latch and a gray door with an acrylic window. It can be mounted in various ways, including panel, 2-inch pipe, or surface mounting method
Honeywell / DR4500
This standard circular chart recorder has two input channels compatible with T/C, RTD, Radiamatic, mV, 0–5V, and 4–20mA signals. It connects through an RS485 Modbus RTU interface and supports multiple mounting options including panel, 2-inch pipe, and surface. The device features a gray door with an
Honeywell / SmartLine
This differential pressure transmitter features a minimum span of 4.0 H2O (10 mbar) and can handle an upper limit of 400 (1000 mbar) as well as a lower limit of -400 (-1000 mbar). It incorporates two remote seals and a maximum turndown ratio of 100:1 for versatile performance. The unit outputs analo
Honeywell / DR4500
This recorder features dual input channels compatible with T/C, RTD, Radiamatic, mV, 0–5V, and 4–20mA signals. It supports a 12-inch diameter chart, and its design includes a gray door with a glass window. The device utilizes a standard pen for recording data, and it is equipped with a standard door
Honeywell / DR4500
This circular chart recorder operates with input channels featuring T/C, RTD, Radiamatic, as well as mV, 0–5V and 4–20mA types. It employs a standard pen for recording and is not equipped with external interfaces or outputs. The device allows for various mounting methods, including panel, 2-inch pip
Honeywell / DR4500
Designed for versatility, this recorder supports inputs such as T/C, RTD, Radiamatic, and voltage signals ranging from 0–5V and 4–20mA. The DR45AT-1000 features a standard pen for chart recording and operates effectively within an ambient temperature span of 0 °C to 55 °C. Additionally, it includes
Honeywell / UDC3500
This controller supports single-loop control and features a communication interface that includes a current output along with four digital inputs. It operates effectively within a humidity range of 10 to 90% and temperature settings from 15 °C to 55 °C, all while ensuring compliance with CE, UL, and
Honeywell / UDC3500
This digital controller features dual 2-amp relays for Form A outputs, allowing for functions such as heat/cool and position proportional control. It includes three Form C E-M relay outputs rated for 5 Amps each, and inputs accommodate TC, RTD, and mV signals, as well as 0-5V and 1-5V inputs with cu