Free UPS Ground on All Parcel Orders!
+1 (919) 205-4392

Search Results

969 results

969 results
Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more
Products

DC2900-C0-3S0-220-000-00-0

DC2900-C0-3S0-220-000-00-0

Honeywell / UDC2800

This digital controller allows for a primary output of either 4 to 20 mA or 0 to 20 mA. It supports dual inputs, accommodating TC, RTD, mV, and multiple voltage ranges. The device is certified to CE standards and facilitates communication via a 10/100M Base-T Ethernet interface (Modbus RTU).

Call
DC2800-RE-2S0-240-100-00-0

DC2800-RE-2S0-240-100-00-0

Honeywell / UDC2800

This controller features two relay outputs: dual Form A relays rated for 2 amps and a Form C E-M relay with a 5-amp capacity. Additionally, the unit accepts diverse input types, including TC, RTD, mV, and current signals ranging from 0-20mA or 4-20mA. It also includes an RS-485 Modbus communication

Call
DC2800-CB-1F0-220-100-00-0

DC2800-CB-1F0-220-100-00-0

Honeywell / UDC2800

Operating as a digital controller within the UDC2800 series, this unit handles inputs from thermocouples, RTDs, and multiple voltage and current types. With CE, UL, and CSA certifications, it meets essential compliance standards. The controller features outputs for both current and alarm relay, maki

Call
DC2800-CE-2S0-220-100-00-0

DC2800-CE-2S0-220-100-00-0

Honeywell / UDC2800

The UDC2800 series features two configurable inputs, accommodating a range of signals such as 0-5V, 1-5V, and 4-20mA. It operates within a 100 to 240 VAC power range and is designed with an RS-485 Modbus communication interface for easy integration. The controller can function in temperatures rangin

Call
DC2800-CE-2S0-210-100-00-0

DC2800-CE-2S0-210-100-00-0

Honeywell / UDC2800

Featuring two inputs, this unit handles TC, RTD, mV, and voltage signals (0-5V, 1-5V, and 0-10V). The controller is certified by CE, UL, and CSA, ensuring compliance with recognized safety standards. It offers an RS-485 Modbus communication interface along with auxiliary output and digital input cap

Call
DC3500-TE-0000-200-00000-00-0

DC3500-TE-0000-200-00000-00-0

Honeywell / UDC3500

Configured with a single control loop, this digital controller supports inputs such as TC, RTD, and several voltage and current options. The controller features three relay outputs with a rating of 5 amps each and includes an open-collector transistor output.

Call
DC2800-EE-1S0-240-000-00-0

DC2800-EE-1S0-240-000-00-0

Honeywell / UDC2800

This digital controller includes multiple input capabilities: it can handle TC, RTD, and mV inputs along with voltage and current signals ranging from 0-5V, 1-5V, 0-10V, 0-20mA, and 4-20mA. Additionally, it features a slidewire input that necessitates two relay outputs. The device is certified to CE

Call
DC3500-0E-0000-100-00000-00-0

DC3500-0E-0000-100-00000-00-0

Honeywell / UDC3500

This digital controller supports one input channel capable of handling TC, RTD, and mV signals, in addition to both 0-5V and 1-5V inputs. The device is built for a broad relative humidity range of 10% to 90% (non-condensing) and can endure ambient temperatures from 15 °C to 55 °C. The unit does not

Call
DC2800-EE-0S0-220-100-00-0

DC2800-EE-0S0-220-100-00-0

Honeywell / UDC2800

This digital controller features dual outputs: one is a Form C electro-mechanical relay rated for 5 Amps, while the second output also provides a Form C relay with an alarm feature. The unit supports a wide range of temperature and humidity conditions, thriving in environments from 0 °C to 55 °C and

Call
DC2800-C0-1F0-200-100-00-0

DC2800-C0-1F0-200-100-00-0

Honeywell / UDC2800

This digital controller accommodates input signals from thermocouples, resistance temperature detectors (RTD), and millivolt inputs, as well as multiple voltage and current ranges including 0-5V, 1-5V, and 0-10V. It is suitable for installation at altitudes up to 2000 meters, operating efficiently w

Call
Showing 761-770 of 969 results