969 results
Honeywell / UDC2800
This unit features control outputs, including a current output of 4 to 20mA or 0 to 20mA, and a Form C electro-mechanical relay rated for 5 Amps. Input options support TC, RTD, mV, and various voltage inputs, specifically 0-5V, 1-5V, and 0-10V. It operates efficiently within an altitude of 2000m, ha
Honeywell / UDC2800
This digital controller features a control output of 4 to 20mA or 0 to 20mA, ensuring compatibility with various systems. It accepts inputs including thermocouples (TC), resistance temperature detectors (RTD), and millivolt signals, along with voltage inputs of 0-5V, 1-5V, and 0-10V. Operating in en
Honeywell / UDC1200
This controller works within an input range of 90 to 264 volts AC and operates at frequencies between 50 and 60 Hz. Its operating temperature spans from 0°C to 55°C while the storage temperature allows for a range of -20°C to 80°C. The unit is rated for relative humidity between 20% and 95% non-cond
Honeywell / UDC2800
Operating efficiently within a temperature range of 0°C to 55°C, this device also maintains performance in relative humidity levels from 5% to 90%, avoiding condensation issues. It is suitable for installation at high altitudes up to 2000 meters and can withstand vibration frequencies of up to 70 Hz
Honeywell / 3G SmartVFD
This variable frequency drive is capable of operating with a minimum frequency of 50 Hz and a maximum frequency of 60 Hz. It has a substantial rated output current of 16.5 A and features both analog and digital I/O options, including 2 analog inputs, 2 analog outputs, 6 digital inputs, and 2 digital
Honeywell / 7800 Series
With a pilot flame establishing timeframe of 4 to 10 seconds and a main flame timeframe of 10 to 15 seconds, this control is efficient in its operation. The unit can function reliably within a temperature range from -40 °C to 60 °C, ensuring performance across various conditions. It weighs 1 lb and
Honeywell / Other
This device features a single control loop and is equipped with an output relay in its first slot. The communications capability includes Ethernet integration, facilitating easy networking. It operates effectively within a temperature range of 0 °C to 55 °C and can be installed at altitudes up to 20
Honeywell / Other
This glass pH electrode supports a wide variety of applications for both measuring and reference roles. It is adaptable to any mounting position and functions within a temperature range of 0 to 100 degrees Celsius. Direct connections are available for UDA2182, APT2000, and APT4000 devices, and the m
Honeywell / Other
This pneumatic valve operates within an inlet pressure range of 45 to 150 psi. It allows for primary output pressure adjustments from 0 to 25 psi and offers a secondary output that can be set up to 5 psi above the primary rating. Designed for bracket mounting, its diaphragm-operated mechanism includ
Honeywell / Other
This module can handle air velocity sensing and pneumatic control, making it versatile for HVAC systems. It supports a pressure range between 9 to 15 PSI and can manage a maximum pressure of 30 PSI. The device operates at temperatures from 5 to 55 degrees Celsius and relative humidity levels from 5%