967 results
Honeywell / UDC2800
This device operates under conditions with a minimum temperature rating of 55°C and requires a relative humidity level of at least 90% (non-condensing). It is equipped with an electro-mechanical relay for control output and is designed for installation at altitudes up to 2000 meters.
Honeywell / UDC2800
This model features two control outputs: one electro-mechanical relay rated at 5 Amps and another Form C relay that also includes Alarm 1, maintaining a consistent 5 Amp rating. It accepts a wide range of inputs that include thermocouples, RTDs, and a variety of voltage and current signals.
Honeywell / UDC2800
This model incorporates an array of input capabilities, accepting thermocouples (TC), resistance temperature devices (RTD), and millivolt signals along with voltage inputs of 0-5V, 1-5V, and 0-10V. With an operational temperature range from 0°C to 55°C, this unit is designed to function reliably in
Honeywell / UDC1200
As a universal digital controller, the DC1203-1-1-7-0-1-0-0-0 supports a linear mA input type. It has two relay outputs and one output that provides a 4 to 20 mA linear signal. With no communication options available, this controller is straightforward in implementation. It operates efficiently with
Honeywell / UDC1200
This device operates within a frequency range of 50 Hz to 60 Hz and consumes 4 watts of power. The controller can handle operating temperatures from 0°C to 55°C and can be stored in environments between -20°C and 80°C. It maintains functionality with relative humidity levels from 20% to 95% (non-con
Honeywell / UDC1200
This model is equipped with a relay output option in its first slot but does not utilize the second or third slots. It has a digital input option and can function in temperatures from 0°C to 55°C, with a storage range from -20°C to 80°C. Additionally, it is rated for operation at humidity levels bet
Honeywell / UDC1200
This unit features three relay outputs for enhanced control capabilities. It operates within a voltage range of 90 to 264 VAC and is rated for frequencies of 50 to 60 Hz. With an operating temperature range from 0°C to 55°C and a storage temperature range from -20°C to 80°C, it is suited for various
Honeywell / UDC1200
This controller operates within a voltage range of 90 to 264 VAC and supports frequencies of 50 to 60 Hz. It can maintain functionality in temperatures ranging from 0°C to 55°C and can be stored in environments between -20°C and 80°C. The unit also withstands relative humidity levels from 20% to 95%
Honeywell / UDC1200
This limit controller features three available option slots for relay outputs, allowing for flexible configurations. It operates reliably in temperatures ranging from 0°C to 55°C and can be stored in a temperature range of -20°C to 80°C. The unit tolerates relative humidity levels between 20% and 95
Honeywell / UDC1200
This controller works within an input range of 90 to 264 volts AC and operates at frequencies between 50 and 60 Hz. Its operating temperature spans from 0°C to 55°C while the storage temperature allows for a range of -20°C to 80°C. The unit is rated for relative humidity between 20% and 95% non-cond