Honeywell / 7800 Series
This integrated burner control unit features a minimum operating temperature of -40°C and can withstand temperatures up to 60°C. It establishes a main flame in a maximum of 10 seconds, while the pilot flame requires either 4 or 10 seconds. The unit includes lockout interlocks for safety.
Honeywell / Micro Switch
This single-pole enclosed limit switch features a double throw (SPDT) contact configuration and a snap action mechanism. The LSYMB4NX-FP switch can handle a current rating of 20 A for AC and 0.5 A for DC applications. It is designed for an operating force of 17.79 N and can manage a horsepower ratin
Honeywell / Other
This probe weighs 1.24 lbs and has a remote mounting capability, providing flexibility in installations. It is equipped with a 100-foot cable for easy placement. The operating temperature range extends from 2 °C to 60 °C, while the storage temperature retains the same thresholds. The device achieves
Honeywell / Other
The 51404926-501 supports various sensing applications while operating in temperature ranges from 0 to 40 degrees Celsius. It maintains optimal functionality under relative humidity levels of up to 80%, both during operation and storage. This sensor board can be utilized at altitudes reaching 1000 m
Honeywell / Other
This 1/8 DIN indicator operates efficiently at a power rating between 90 to 264 VAC, with frequency capabilities ranging from 50 Hz to 60 Hz. Its operational temperature range extends from 0°C to 55°C, while it can be stored at temperatures between -20°C and 80°C. With a weight of 0.46 lbs, it is li
Honeywell / Other
This controller operates on a dual-pipe system and functions effectively with a liquid-filled remote bulb sensing element. With a maximum sensing element temperature of 110°C and a controller temperature limit of 66°C, it ensures reliable performance. The capillary length extends to 5 feet, facilita
Honeywell / Other
The RP920A1025 model features an input signal range of 3 to 15 psi and can output between 3 and 13 psi. Its design accommodates a minimum air pressure of 15 psi and a maximum of 30 psi, ensuring reliability in pneumatic systems. The controller operates effectively in temperatures between 5°C and 55°
Honeywell / Other
This valve assembly operates efficiently in temperatures ranging from a minimum of 40°F to a maximum of 120°F. It can endure relative humidity levels of up to 80% without condensation during operation and storage. Designed for operation at altitudes up to 1000 meters above sea level, it is optimized
Honeywell / Other
This detector is rated for a frequency of 60 Hz and weighs 17.6 lbs. It features a mounting connection suitable for a 1-inch NPT sight pipe and connects electrically via a terminal block. Compatible with several flame amplifiers, including R7476 and R7886, it is crafted from aluminum and cadmium-pla
Honeywell / Other
This device operates effectively across a voltage frequency range of 50 to 60 Hz. It features an IP 65 enclosure rating, which protects the unit against dust and water. Additionally, the tightness control unit supports a maximum inlet pressure of 500 mbar and a minimum inlet pressure of 10 mbar. Its