966 results
Honeywell / Other
This temperature controller weighs 1.50 lbs and utilizes a 20-foot capillary tube for remote bulb placement. It offers full-load current ratings of 8.0 A at 120 V, along with locked rotor ratings of 48.0 A at the same voltage. At 240 V, the full-load current is rated at 5.1 A with a locked rotor rat
Honeywell / Other
Designed for two-pipe systems, this thermostat withstands an air pressure rating of up to 25 psi. It utilizes 1/4-inch O.D. barb fittings for air connections and integrates a liquid-filled sensing element housed within a 3/8-inch diameter bulb. The capillary length measures at 914 mm, contributing t
Honeywell / Other
This model has an IP54 rating that protects it from dust and water splashes, ensuring durability. It operates efficiently within a temperature range of -40 °C to 55 °C and can be stored in conditions from -40 °C to 60 °C. The device supports relative humidity levels from 5% to 95%, further enhancing
Honeywell / Other
This UV flame detector weighs 6 lbs and has a robust NEMA 4 rating for environmental protection. It is effective in temperatures ranging from -40°C to 79°C, accommodating various operational situations. This device includes a self-check function where an oscillating shutter interrupts the UV signal
Honeywell / Other
This diaphragm valve features a straight-through, non-offset pattern for enhanced flow efficiency. Rated for a maximum operating pressure of 1 PSI, it boasts a flow capacity of 4178 CFH. The unit is constructed from die-cast aluminum and functions well in ambient temperatures ranging from 0°C to 52°
Honeywell / Other
This gas valve features a maximum operating pressure of 0.5 psi (3.4 kPa) and regulates pressure through two stages, accommodating low-fire and high-fire conditions. It comes equipped with an NPT threaded pipe connection and is designed for 1-1/2 inch pipe sizes. The opening cycle of the valve varie
Honeywell / Other
This module features a two-row by twenty-column vacuum fluorescent display (VFD) and utilizes the Modbus communication protocol. Designed for robust performance, it can handle power dissipation up to 7 watts and a maximum power consumption of 2 VA. Operating temperatures range from -40 °C to 60 °C,
Honeywell / Other
This tightness control unit features adjustable measurement times from 5 to 30 seconds, with a factory default of 30 seconds. It has a weight of 0.92 lbs and supports an operational altitude up to 2000 meters. The unit can withstand a maximum inlet pressure of 500 mbar and a minimum of 10 mbar, ensu