969 results
Honeywell / UDC3500
This digital controller features a weight of 3 lbs and includes three Form C E-M relay outputs rated for 5 Amps each. Additionally, it has two outputs consisting of dual Form A 2-Amp relays and accepts diverse input types such as TC, RTD, mV, and multiple current ranges. It operates within a relativ
Honeywell / UDC3500
This controller features multiple input options including TC, RTD, and mV signals, along with standard voltage and current inputs like 0-5V, 1-5V, 0-20mA, and 4-20mA. It incorporates a total of three relay outputs (5 Amps) alongside dual form A relays for heating and cooling processes. Certification
Honeywell / UDC3500
The Honeywell DC3501-CE-3E0C-200-10000-00-0 digital controller features a single control loop and supports various input signals including TC, RTD, mV, and different current and voltage ranges. It has a communication interface that utilizes 10 Base-T Ethernet and Modbus RTU, while providing 4 digita
Honeywell / UDC3500
This digital controller supports a variety of inputs, including TC, RTD, mV, 0-5V, 1-5V, 0-20mA, and 4-20mA. There are three Form C electro-mechanical relay outputs rated at 5 Amps each, along with an additional Form C relay. Operating within a single control loop, the unit does not have a real-time
Honeywell / UDC3500
This digital controller accepts multiple inputs, including TC, RTD, millivolt signals, and various voltage and current ranges. The unit is designed for single-loop control and operates effectively within specified temperature and humidity ranges.
Honeywell / UDC3500
This digital controller supports multiple input types including thermocouples (TC), resistance temperature detectors (RTD), and milliVolt (mV) configurations as well as various voltage and current signals. It is certified to CE standards and operates efficiently within a range of conditions.
Honeywell / UDC2800
This controller offers a variety of input options including TC, RTD, and multiple voltage ranges. It performs effectively at ambient temperatures between 0 °C to 55 °C and has multiple output capabilities, including a Form C relay. Additionally, it is UL, CE, and CSA certified to ensure compliance w
Honeywell / UDC2800
This digital controller includes two Form C electro-mechanical relay outputs rated at 5 Amps. The device features a communication interface with one auxiliary output and the option for up to two digital inputs. Relative humidity can range from 5% to 90% (non-condensing), and it operates effectively
Honeywell / UDC2800
This digital controller includes flexibility in its inputs, supporting TC, RTD, mV, and voltage signals from 0-5V, 1-5V, and 0-10V. It is equipped with one auxiliary output and one or two digital inputs. The device operates within a relative humidity range of 5% to 90%, is rated for ambient temperat
Honeywell / UDC2800
This digital controller features a primary output that can be configured for either 4 to 20 mA or 0 to 20 mA. It is equipped with an alarm relay and facilitates multiple input types, including thermocouples, RTDs, and several voltage/current specifications. Rated for a humidity range of 5% to 90% (n