966 results
Honeywell / Other
This gas detector features a measuring range of 0 to 100% LEL and delivers a 4-20 mA signal output, which can either sink or source, along with HART communication capabilities. With a robust IP66/IP67 rating and a wide operating temperature range from -40°C to +65°C, it is suitable for demanding env
Honeywell / Other
This refrigerant sensor is adaptable for continuous monitoring across multiple applications, including chiller plants, cold storage facilities, and food processing environments. It can function effectively at a maximum relative humidity of 80% without condensation and at altitudes up to 1000 meters.
Honeywell / Other
With a weight of 2.33 lbs, this sensor functions at a voltage rating of 12 VDC and utilizes infrared sensing technology. It measures refrigerant concentrations within a range of 0 to 1000 ppm, with a detailed resolution of 1 ppm. Its enclosure is made from durable ABS-Polycarbonate, offering adequat
Honeywell / Other
This controller accommodates a voltage input range of 17-27 VAC or 18-36 VDC. It operates effectively in temperatures ranging from -20 °C to 50 °C, making it suitable for diverse environments. The unit can communicate using the RS-485 Modbus protocol, and it is capable of supporting up to 96 wired a
Honeywell / Other
This flame detector is rated IP65 for protection against dust and water. It operates efficiently in temperatures from -40°C to 70°C in standard environments, while it can function between -25°C and 70°C in ATEX/IECEx/FM certified areas. Storage conditions are the same, ranging from -40°C to 70°C.
Honeywell / Other
The pressure transducer offers exceptional linearity of ±0.10% full scale and an impressive hysteresis of ±0.05% full scale. It remains hermetically sealed and possesses an IP68/NEMA 6P rating, making it resistant to harsh environmental conditions. With a compensated operating temperature range from
Honeywell / Other
This device accommodates an input voltage frequency of 50/60 Hz and operates at a current rating of 500 mA. The unit is functional across a temperature range of -20°C to 50°C and can withstand humidity levels from 0 to 95% relative humidity, ensuring reliability in diverse environments. Networking c
Honeywell / Other
This device weighs 1.06 lbs and is built to perform in temperatures from -20°C to 40°C, with humidity levels acceptable from 20% to 90% RH. It provides a 4-20 mA analog output signal and is equipped with a backlit 122 x 32 dot display along with a green status LED. A six-function touch-sensitive key
Honeywell / Other
This transducer is temperature compensated across a range of 15°C to 71°C and exhibits a high degree of accuracy with ±0.10% full scale measurement. The device also features linearity and hysteresis ratings of ±0.10% and ±0.05% full scale, respectively. Its robust construction includes a case made f
Honeywell / Other
This load cell exhibits a non-linearity accuracy of ±0.1% of full scale and a hysteresis of ±0.08%. It operates effectively within a temperature range of -54°C to 121°C, with temperature compensation guaranteed between 15°C and 71°C. The output signal is non-amplified, providing 3 mV/V ±0.5% FS, sui