753 results
Honeywell / HercuLine 2001
This actuator operates on a single-phase system and weighs 27 lbs. It requires a power supply of 100 to 130 VAC and operates at an input frequency of 60 Hz. Input signals can be analog, supporting ranges of 0/4-20 mA, 0/1-5 Vdc, or 0-10 Vdc, and it includes two auxiliary switches for additional cont
Honeywell / HercuLine 2001
This model from the HercuLine 2001 series weighs 27 lbs and is capable of 90 degrees of rotation. It is designed for single-phase operation and can operate on a power supply ranging from 100 to 130 VAC at an input frequency of 60 Hz. The actuator accepts multiple analog input signals, such as 0/4-20
Honeywell / DR4500
This circular chart recorder measures 12 inches in diameter and is capable of functioning within an operating temperature range of 0 °C to 55 °C. It has a weight of 13.2 lbs, facilitating various mounting methods including panel, 2-inch pipe, or surface options. The device operates effectively with
Honeywell / UDA2182
This universal analyzer allows for dual-channel monitoring of pH and ORP. It features a graphical LCD display with backlighting for visibility and is equipped with a 10-button membrane keypad for user interaction. Operating temperatures range from 0 to 60 °C, and it can be stored between -30 and 70
Honeywell / HercuLine 2000
This actuator boasts a rated torque of 45.0 Nm and rotates up to 150 degrees. It operates on single-phase power, with a supply range of 100 to 130 VAC and an input frequency of 60 Hz. The device features a dual analog output with 1000 ohm signals and includes two auxiliary switches for added functio
Honeywell / ControlEdge HC900
This CPU module features a non-redundant controller architecture. With the capability to accommodate 2,000 function blocks, it supports up to 1,152 universal analog inputs. It also allows for a maximum of 480 analog outputs with internal power and up to 2,304 outputs with external power. This device
Honeywell / SmartLine
The STD720-E1HC6AS-1-A-AD0-11S-A-10A0-0 0-0000 differential pressure transmitter supports a maximum turndown ratio of 100:1. The unit operates within a temperature range of -40 to 85 °C and features an analog output of 4-20 mA DC. It utilizes silicone oil as the fill fluid and has a dual-ended head
Honeywell / SmartLine
This differential pressure transmitter includes a maximum turndown ratio of 100:1. The URL is set at 400/1000 mbar, while the LRL measures from -400 to -1000 mbar. It implements a 4-20mA DC analog output and utilizes silicone oil 200 as the fill fluid, ensuring reliable operation.
Honeywell / GR Series
Optimized for performance, this industrial recorder has a weight of 3.3 lbs and grants 1 GB of internal data storage. The device accommodates DIN and panel mounting for flexible installation options. It operates effectively in temperatures ranging from 0°C to 50°C and supports a humidity range of 10
Honeywell / SmartLine
Designed for a temperature range of -40 to 85 °C, this transmitter provides accurate readings with a maximum turndown ratio of 100:1. Employing both 316 stainless steel for the process head and diaphragm ensures durability. With an operational range extending from -400 to 1000 mbar, this device feat