966 results
Honeywell / Other
Designed to provide effective flame monitoring, this detector operates in ambient temperatures ranging from -4 °C to 79 °C. It has an IP66 rating for dust and water resistance and supports mounting in any orientation. This device is compatible with several amplifiers and is recognized by both BGC an
Honeywell / Other
This valve features a 2-inch NPT pipe size and has a maximum operating pressure of 0.5 psi (3.4 kPa). Designed for temperatures ranging from -40°C to 66°C, it also has an opening time of between 3 to 25 seconds, with a closing time of up to 2 seconds. Mounting is recommended in an upright or horizon
Honeywell / Other
This valve features a pipe size of 1-1/4 inches (DN32) and has a large flow body design, ensuring optimal performance at a maximum operating pressure of 0.5 psi (34 mbar). It can modulate from 14% to 100% of the burner load, providing precise control. Electrical connections are made via a DIN 43650
Honeywell / Other
This shut-off valve boasts a flow capacity of 5,070 CFH, making it suitable for high-demand applications. It functions effectively under an operating pressure of 2.0 Psi, with valve opening and closing times of under one second. Constructed from die-cast aluminum, it features a straight-through, non
Honeywell / Other
This diaphragm valve features a straight-through, non-offset pattern for enhanced flow efficiency. Rated for a maximum operating pressure of 1 PSI, it boasts a flow capacity of 4178 CFH. The unit is constructed from die-cast aluminum and functions well in ambient temperatures ranging from 0°C to 52°
Honeywell / Other
This diaphragm gas valve boasts a 2-inch NPT pipe connection and is made from durable cast aluminum. It operates at an input voltage of 120 VAC and a frequency of 60 Hz. The opening and closing timing of this valve is 5 seconds and 2 seconds, respectively, and it operates safely at 1 PSI. A bleed ta
Honeywell / Other
This ultraviolet flame detector can withstand a maximum pressure of 5 psi (34.5 kPa). It is constructed with an enclosure rated for NEMA 4 and 4X standards, ensuring durability in challenging environments. The UV sensing tube, which is field-replaceable, offers a lifespan of up to 40,000 hours when
Honeywell / Other
This module features a two-row by twenty-column vacuum fluorescent display (VFD) and utilizes the Modbus communication protocol. Designed for robust performance, it can handle power dissipation up to 7 watts and a maximum power consumption of 2 VA. Operating temperatures range from -40 °C to 60 °C,