966 results
Honeywell / Other
With a rated frequency of 60 Hz, this damper motor has an opening current rating of 0.37 A and a holding current rating of 0.12 A. The power consumption for opening is 28 W, while holding requires 8.5 W. It features a gray enclosure and includes a built-in thermal breaker for overload protection.
Honeywell / Other
Designed with a gray enclosure, the T991A1194 incorporates an analog output connected to a 135-ohm potentiometer. It features one sensor input with a remote copper bulb element and has a 20-foot capillary tube for flexible installation. The device allows setpoint adjustments via an external knob and
Honeywell / Other
This economizer module operates effectively with a logic module and is designed to support a range of sensors to optimize air quality management. It functions between a minimum temperature of 0 degrees Celsius and a maximum temperature of 40 degrees Celsius, displaying reliable performance in varied
Honeywell / Other
The RP7517B1024 transducer ensures an output pressure range from 3 to 15 psi and can withstand maximum operating pressure of 30 psi. Rated for power consumption at 1.7 VA, it features a direct acting mechanism and uses screw terminals or lead wires for electrical connections. With operational temper
Honeywell / Other
Equipped with four SPDT relay outputs and two analog outputs, this temperature controller is designed for straightforward integration into existing systems. It operates efficiently across a temperature range from -40°C to 60°C and can function properly at relative humidity levels between 5% and 95%,
Honeywell / Other
This detector is rated for a frequency of 60 Hz and weighs 17.6 lbs. It features a mounting connection suitable for a 1-inch NPT sight pipe and connects electrically via a terminal block. Compatible with several flame amplifiers, including R7476 and R7886, it is crafted from aluminum and cadmium-pla
Honeywell / Other
This flame detector weighs 14.5 lbs and features a lead wire length of 96 inches for flexible installation. It is intended for flange mounting and can operate in temperatures ranging from -20 °C to 70 °C. For storage, it endures conditions as low as -50 °C and as high as 80 °C, ensuring durability a
Honeywell / Other
This detector is rated for an electrical input of 120/230 VAC, operating at frequencies of 50/60 Hz. With an impressive ambient temperature range from -40°C to 79°C, it is versatile in application. The device features a self-check function that utilizes an oscillating shutter to test the sensor tube
Honeywell / Other
Designed to provide effective flame monitoring, this detector operates in ambient temperatures ranging from -4 °C to 79 °C. It has an IP66 rating for dust and water resistance and supports mounting in any orientation. This device is compatible with several amplifiers and is recognized by both BGC an
Honeywell / Other
Constructed from die-cast aluminum, this valve maintains a maximum operating pressure of 2 psi and allows for a substantial valve capacity of 6100 cubic feet per hour. It features a rapid opening time of under 1 second and includes positive close-off with upstream and downstream pressure testing tap