FA-N311310-1

FA-N311310-1

Johnson Controls / Metasys FA

This analog input module accepts several input voltage ratings, specifically 0-10V, 0-5V, 1-5V, and 4-20mA, along with current ratings of 4-20mA and 0-20mA. It exhibits an impressive input accuracy of +/- 0.1% and features high input impedance. Measuring 190 mm in length, 35 mm in width, and 83 mm i

Available
FIC-101-1

FIC-101-1

Johnson Controls / Metasys FA

This field interface controller model features a configuration of 6+6 analog inputs and is capable of handling input currents ranging from 0 to 20 mA. Its input impedance stands at 100 ohms, making it adaptable to various sensors. The device can operate within a temperature range of 0 to 55 degrees

In Stock Ships Today
DT-9100-8104

DT-9100-8104

Johnson Controls / Metasys DX

This terminal requires a power supply of 24 VAC ±15% at a maximum of 4 VA or a nominal 9-18 VDC with a consumption of 50 mA at 12 VDC. Communication is managed through an RS-232 asynchronous protocol operating at 9600 baud in half-duplex mode. Its compact size conveniently fits various installation

Available
M4-SNC25150-4

M4-SNC25150-4

Johnson Controls / M4 Controllers

The M4-SNC25150-4 network controller supports Ethernet communication and includes 40 onboard I/O. It can handle an operating temperature from 0°C to 50°C and has an impressive storage temperature range of -40°C to 70°C. This unit is compatible with several field buses, like BACnet MS/TP and LonWorks

Call
NU-NCM300-700

NU-NCM300-700

Johnson Controls / Metasys NU

Part of the Metasys NU series, the NU-NCM300-700 operates effectively from 0°C to 50°C. The module is compact and weighs 1.51 kg (3.33 lbs.), designed for either DIN rail or panel mounting. It requires a current of 0.55A / 0.3A and is compatible with Metasys VDC Logic I/O systems, enabling integrati

Call
NU-NET301-700

NU-NET301-700

Johnson Controls / Metasys NU

The NU-NET301-700 serves as a network interface module, providing robust Ethernet connectivity. This component operates effectively within a temperature range of 0°C to 50°C (32°F to 122°F) and is designed for use with Johnson Controls Metasys NCM systems. It fits conveniently into an NCM slot and u

In Stock Ships Today
MS-IOM4710-0

MS-IOM4710-0

Johnson Controls / Metasys MS

This I/O module cover accommodates a frequency of 50/60 Hz and supports surface mounting with screws and three clips, as well as mounting on a 35 mm DIN rail. It covers modules with a power consumption typically of 10 VA, with a maximum of 15 VA. It can operate within temperatures from 0 to 50 degre

In Stock Ships Today
FA-VAV110-1

FA-VAV110-1

Johnson Controls / Metasys FA

This Variable Air Volume Controller features 6 analog inputs, accommodating voltage ranges of 0 to 2 volts DC or 0 to 10 volts DC. It includes 4 binary inputs and supports either 0 or 2 analog outputs with a voltage range of 0 to 10 VDC. For current output, it provides 10 mA. The device also has up

Call
M4-SNC16121-04

M4-SNC16121-04

Johnson Controls / M4 Controllers

The M4-SNC16121-04 incorporates 28 onboard points for inputs and outputs and supports transmission speeds of 10 or 100 Mbps. It can handle a maximum of 50 MSTP devices and functions effectively within a non-operating temperature range from -40°C to 70°C. The mounting options for this unit include a

Call
MS-FEU2610-0U

MS-FEU2610-0U

Johnson Controls / Metasys MS

This field equipment controller features 6 universal inputs, 2 binary inputs, 3 binary outputs, and 2 analog outputs. It supports 4 configurable outputs, enhancing flexibility for different applications. For operational efficiency, it functions within a temperature range of 32 to 122 degrees Fahrenh

Available