Johnson Controls / Metasys NU
Part of the Metasys NU series, the NU-NCM300-700 operates effectively from 0°C to 50°C. The module is compact and weighs 1.51 kg (3.33 lbs.), designed for either DIN rail or panel mounting. It requires a current of 0.55A / 0.3A and is compatible with Metasys VDC Logic I/O systems, enabling integrati
Johnson Controls / Metasys MS
This Johnson Controls controller features six universal inputs, two binary inputs, and two binary outputs. Additionally, it provides two analog outputs and four configurable outputs, supporting versatile application requirements. It operates on a nominal power supply of 24 VAC, with a voltage range
Johnson Controls / M4 Controllers
This network controller supports a maximum power consumption of 38 VA. It operates effectively in 10% to 90% humidity and can manage up to 50 MSTP devices. It maintains functionality under various conditions with a temperature range for operation between 0°C and 50°C. The housing is made from a dura
Johnson Controls / Metasys MS
The MS-BTCVTCBL-700 cable replacement set is engineered specifically for networking purposes within the Metasys MS series. This 1.5-meter cable is lightweight at around 0.14 kilograms. Its retractable design facilitates convenient storage and accessibility. It is designed to work efficiently at 50/6
Johnson Controls / Metasys MS
The MS-IOU4710-0U is an I/O module designed to handle a total of 17 I/O connections. This module operates with a nominal supply voltage rating of 24 V AC within a supply voltage range of 20 to 30 V AC. It supports both smoke control functions and runs at a frequency of 50/60 Hertz. With a weight of
Johnson Controls / Metasys MS
This modular air controller weighs approximately 1.06 kg and operates within an ambient temperature range of 0 to 50°C. It can be stored safely at temperatures from -40 to 70°C. The communication interface supports the N2 Open Protocol and BACnet MS/TP Protocol for integration into broader systems.
Johnson Controls / Metasys AS
This Johnson Control's actuator functions effectively with control signals ranging from 0 to 10 VDC or 4 to 20 mA for modulating control. It can be mounted directly on valve assemblies or via brackets. The unit performs well in operating temperatures between 0°C and 50°C, and it is designed to handl
Johnson Controls / M4 Controllers
The M4-SNC16121-04 incorporates 28 onboard points for inputs and outputs and supports transmission speeds of 10 or 100 Mbps. It can handle a maximum of 50 MSTP devices and functions effectively within a non-operating temperature range from -40°C to 70°C. The mounting options for this unit include a
Johnson Controls / Metasys FA
Designed for detailed monitoring, the FIC-101-701 features analog input channels configured as 12+12. This unit handles input currents from 0 to 20 mA with an input impedance of 120 ohms. It operates effectively between 0 to 55 degrees Celsius and is compatible with standard frequencies of 50/60 Hz.
Johnson Controls / M4 Controllers
This network controller operates effectively across a temperature range of 0°C to 50°C and can withstand non-operating temperatures from -40°C to 70°C. Powering the unit requires a supply of 24 VAC in North America or a SELV standard in Europe, with maximum power consumption rated at 38 VA. Addition