71 results
Johnson Controls / Other
This variable air volume modular assembly controller features a minimum actuator torque of 4 N·m (35 lb·in) and weighs 2.8 lbs. Operating at a power consumption of up to 10 VA, it includes an optional fuse rated at 0.6 A. It can operate within a temperature scope from 0°C to 50°C while remaining fun
Johnson Controls / Other
This unit features a coiled bulb as its sensing element, providing reliable temperature readings. The operating range for set points is between -7 °C and 27 °C. With a weight of 5 lbs, the device has a current rating of 16.0/9.2/8.0 A depending on the voltage used. The built-in Single-Pole, Double-T
Johnson Controls / Other
Designed with a remote pressure-reducing valve (PRV) connection of 3/8 inch and a local panel connection of 1/2 inch, this station suits various installation requirements. It maintains a nominal outlet pressure of 20 psig and allows for single PRV options while requiring compressor air quality of le
Johnson Controls / Other
With an impressive efficiency rating exceeding 99.999% for particles measuring 0.025 microns and larger, this filter provides exceptional contaminant removal. The filter operates effectively at a nominal flow rate of 40 SCFM and supports a maximum of 50 SCFM. It is designed to handle input pressures
Johnson Controls / Other
This controller offers 6 analog inputs and 6 binary inputs utilizing 24 Volts AC with a minimum current requirement of 10 mA. It supports both surface and DIN rail mounting, enhancing its adaptability in installation. With a broad operating temperature range of -40°C to 60°C, it can function effecti
Johnson Controls / Other
This repeater utilizes an RS-485 to RS-485 communication protocol and can function efficiently in environments with temperatures ranging from -25 °C to 70 °C. It can accommodate a wire range between 14 to 26 AWG and operates under half-duplex conditions. The device can handle baud rates from 600 to
Johnson Controls / Other
This unit features connections for remote PRV at 3/8 inches and a local panel connection at 1/2 inches. It operates within a maximum input pressure of 150 psig and maintains a temperature limit of 52°C. Equipped with a four-way bypass valve, it uses activated and coalescing carbon filters for effect
Johnson Controls / Other
Equipped with a rectangular duct configuration of 48 x 18 inches, this module features insertion mounting secured with stainless steel hardware. It operates efficiently with a calibrated velocity range of 0 to 5,000 feet per minute (FPM) or 0 to 1,524 meters per minute (MPM). The standard output sig
Johnson Controls / Other
This device is equipped for standard equal area distribution of sensors and can accommodate up to 128 sensors. It requires a power input of 24 Volts AC, with a maximum consumption of less than 10 VA. Communication capabilities include a 2-wire RS-485 bus and support for BACnet MS/TP and Modbus RTU p