Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Featuring three poles, this circuit breaker uses a thermal magnetic trip unit for reliable operation. It provides notable interrupt capacities of 65 kAIC at 240 volts AC, 22 kAIC at 480 volts AC, and 10 kAIC at 250 volts DC. Its design facilitates easy installation and wire connections, accommodatin
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features a J frame and comes equipped with fixed thermal and fixed magnetic trip types. It offers a solid interrupting rating of 65 kAIC at 480 volts and 100 kAIC at 240 volts, ensuring effective fault clearing. Designed with aluminum terminals, the HJD3225 maintains high perfor
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
With a robust operating temperature range from 0°C to 40°C, the A1X5PK is tailored for demanding environments. This unit also supports storage conditions between 0°C and 40°C, while maintaining operation in humidity levels up to 80% without condensation. Its suitable installation altitude reaches up
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Constructed with a K frame, the KDB3350 is specified for a frequency range from 50 Hz to 60 Hz. It features line and load terminals made from aluminum. The trip type is designated as T186 and it has an interrupting capacity of 65 KAIC at 240 VAC and 35 KAIC at 480 VAC.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This device includes a total of four auxiliary contacts, consisting of two normally open (NO) and two normally closed (NC). The switch supports a right-hand mounting orientation, operates on a single phase, and features trip indication functionality.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This rating plug supports 3-pole breaker frames and is designed to be mounted easily by plugging into compatible trip units. It is engineered for use with several molded case circuit breaker frames, including LD, HLD, and others. The interrupting rating is 65 kAIC at 480 VAC, ensuring robust perform
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features three poles and incorporates a non-interchangeable thermal-magnetic trip mechanism. Its interrupting capacity is rated at 25 KAIC for operations at 415 VAC. Installation can occur at altitudes of up to 1000 MSL, and it performs effectively in environments with non-conde
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Engineered for Frame L, this trip unit utilizes adjustable short-time settings, allowing for customization based on application requirements. It functions effectively at installation altitudes up to 1000 meters, with a humidity tolerance of 80% for both operation and storage.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features three poles and utilizes T186 trip technology for effective protection. With rated voltages of 600 VAC and 250 V DC, it provides significant versatility in various applications. The device supports interrupt ratings of up to 35 KAIC at 480 VAC and 65 KAIC at 240 VAC, en
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This accessory supports thermal-magnetic tripping functions (LI) and is compatible with both J and K frame sizes. It performs optimally within a temperature range of -20 °C to 70 °C for operation and -40 °C to 80 °C for storage.