507 results
Schneider Electric / PowerPact
The circuit breaker operates at a rated voltage of 240 V and supports a breaking capacity of 10 kA, designated under code B. It employs thermal-magnetic trip unit technology and can handle a magnetic tripping current of 2400 A while maintaining a magnetic hold current of 1200 A. Designed for use wit
Schneider Electric / PowerPact
This circuit breaker features a control type with an operating handle and is designed for use in networks with an operational voltage of 240 V AC at a frequency of 50/60 Hz. It incorporates thermal magnetic trip unit technology, allowing it to handle magnetic tripping currents up to 1800 A and maint
Schneider Electric / PowerPact
This circuit breaker features a robust design with dimensions of 6.47 x 3.00 x 3.93 inches and an impulse withstand voltage capacity of 8 kV. It operates at a line rated current of 100 A with a rated voltage of 240 V AC and possesses an interrupting capacity of 100 kA at 240 V AC.
Schneider Electric / PowerPact
With a 3-pole configuration, this automatic switch can interrupt up to 18 kA at 600 V. It possesses a short-circuit withstand capacity of 65 kA at 240 V and 35 kA at 480 V. The device is compatible with conductors ranging from 2 x AWG 3/0 to 500 kcmil and offers an efficient I-Line mounting option.
Schneider Electric / PowerPact
Designed for operational voltages of up to 600 VAC, this circuit breaker supports a frequency range of 50 Hz and 60 Hz. It provides maximum interrupt capacities, measuring up to 65 kA at 240 V, 35 kA at 480 V, and 18 kA at 600 V. The breaker comes equipped with an electronic MicroLogic 3.3 trip unit
Schneider Electric / PowerPact
This circuit breaker utilizes an electronic ammeter type trip unit and provides solid state protection. With an I-Line mounting style, it employs mechanical lugs for load side connections and offers both local signaling via a push-to-trip button and I-Line terminations on the line side. It complies
Schneider Electric / PowerPact
This circuit breaker operates efficiently with a line rated current of 125 A and is equipped with two poles. It has a breaking capacity of 25 kA and functions at a rated operational voltage of 240 V. The breaker utilizes thermal-magnetic trip unit technology.
Schneider Electric / PowerPact
This circuit breaker has two poles and a breaking capacity of 25 kA, with a rated operational voltage of 240 V AC. The device features a magnetic tripping current of 1800 A and is constructed for a continuous current rating of 80%, making it suitable for numerous applications. It utilizes an operati
Schneider Electric / PowerPact
This molded case circuit breaker includes 3 poles and provides electronic trip functionality. It has a substantial interrupting capacity of 18 kA, ensuring reliable performance in high-demand scenarios. The device weighs 11.19 kg and supports unit mounting frame designs.