Siemens / SENTRON
This circuit breaker features a robust interrupting capacity of 35 kA at 480 V, ensuring reliable fault management. Designed for three-phase systems, it incorporates long-time and instantaneous trip functions with a thermal-magnetic protection type classified under Class M. It allows for feed-throug
Siemens / SENTRON
This circuit breaker complies with UL and IEC standards and functions effectively on both 50 Hz and 60 Hz frequencies. It features an interrupting rating of 100 kA at 480 V, providing substantial protection. The thermal-magnetic trip unit and solid-state protection ensure reliability in three-phase
Siemens / SENTRON
The ED22B025 circuit breaker combines a thermal magnetic protection scheme with long-time and instantaneous trip functions. It is rated for an interrupt capacity of 10 KAIC at 240 VAC. Its installation is made easy with a bolt-on connection and load side lug terminals.
Siemens / SENTRON
This device operates with a 1-phase configuration and consists of two poles. It features thermal magnetic trip technology, providing effective protection against overload and fault conditions and ensures compatibility with a frequency range of 50-60 Hz. The framed structure is classified as an ED Fr
Siemens / SENTRON
This device operates with an interrupt rating of 35 kA at 240 VAC and has a burst capacity of 35 kA at 480 V. It employs a thermal magnetic protection method, with functions including long-time and instantaneous trip settings. The connection type for this circuit breaker is bolt-on, and it has an FD
Siemens / SENTRON
This molded case circuit breaker features three poles and utilizes thermal magnetic protection. It supports a significant interrupt rating of 65 KAIC at 480 V. Designed for bolt-on installation, it can function effectively within humidity levels of up to 80% in both operating and storage conditions.
Siemens / SENTRON
This two-pole circuit breaker features a thermal magnetic protection system that includes long time and instantaneous trip functions. It employs a load side lug for terminal connection and uses a bolt-on connection type. Suitable for operation in environments with up to 80% humidity, the device can
Siemens / SENTRON
This circuit breaker features three poles and offers thermal magnetic protection. It has interrupt ratings of 65 kA at 240 VAC and 35 kA at 480 VAC, ensuring reliable operation under fault conditions. Lug terminations are applicable for both line and load sides, but lugs are not included.