Schneider Electric / PowerPact
Engineered for robust performance, the HT3125 trip unit has a thermal-magnetic design to ensure dependable operation with a rating of 125 A. This unit supports three poles and has a short circuit breaking capacity of 80%, complying with UL standards. The NEMA 1 enclosure provides IP20 protection, ap
Schneider Electric / PowerPact
This molded case circuit breaker, rated with a 3-pole design, utilizes a thermal-magnetic trip unit for effective operation. It is certified under numerous standards, such as UL 489 and CE. Measuring 7.5 inches high, 4.09 inches wide, and 3.4 inches deep, it is compatible with an I-Line mounting typ
Schneider Electric / PowerPact
This 3-pole circuit breaker features a rated insulation voltage of 750 V, a breaking capacity of 18 kA, and a compact mounting design. It allows for plug-in modules, including 2 auxiliary switch OF connections, 1 alarm switch SD, and 1 voltage release MN or MX. The device has a weight of 13.2 kg and
Schneider Electric / PowerPact
Rated for 800 amps, this circuit breaker accommodates a voltage rating of up to 600 volts AC. It is housed in a P-frame and facilitates various mounting configurations, including I-line, busbar, and DIN rail. With three poles, the PJA36080 circuit breaker supports both long-time and instantaneous tr
Schneider Electric / PowerPact
This 3-pole circuit breaker utilizes lug terminations on both the load and line sides for secure connections. It features a Micrologic 3.0 LI trip unit with an electronic trip mechanism. The PJL36080U31A can handle substantial interrupt ratings, such as 100 kA at 240V, 65 kA at 480V, and 25 kA at 60
Schneider Electric / PowerPact
This circuit breaker operates at a voltage of 240 V, with frequencies ranging from 50 Hz to 60 Hz. Its considerable breaking capacity is 25 kA, ensuring effective circuit interruption during fault conditions. The device includes a magnetic trip current setting of 1800 A and operates with a magnetic
Schneider Electric / PowerPact
Designed for a maximum operational voltage of 240 V AC, this circuit breaker supports a breaking capacity of 25 kA. Additionally, it operates on a frequency of 50/60 Hz, with a rated impulse withstand voltage of 8 kV. The magnetic trip activates at a current of 2400 A, while it holds at 1200 A, and
Schneider Electric / PowerPact
This circuit breaker features three poles and an operating handle for manual control. It operates at a rated voltage of 240 V AC and is suitable for network frequencies of 50/60 Hz. The thermal magnetic trip unit provides added protection with a magnetic tripping current of 2400 A and a hold current
Schneider Electric / PowerPact
This circuit breaker operates at a rated voltage of 240 V AC and is suitable for network frequencies of 50/60 Hz. It features a breaking capacity of 25 kA and a breaking capacity code of D. The device is rated for 8 kV impulse withstand voltage and includes a magnetic trip setting at 2400 A, with a
Schneider Electric / PowerPact
This unit boasts a breaking capacity of 65 kA, suitable for high-demand situations, and functions at a rated operational voltage of 240 V AC. The QGA32070 incorporates thermal magnetic trip technology, ensuring proactive responses to overload conditions with a magnetic tripping current of 2400 A. It