Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features a J-frame design with three poles, accommodating three-phase power. It has an AC voltage rating of 600 VAC and a DC rating of 250 VDC. The interrupting capacity is rated at 65 KAIC for 240 VAC and 35 KAIC for 480 VAC, ensuring safe operation in fault conditions.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This 3-pole molded case circuit breaker employs fixed long-time and instantaneous trip characteristics. It operates at frequencies of 50/60 Hz and is equipped with load-side lugs for reliable connections. Compliance with UL 489, IEC, and CSA standards ensures its suitability for a variety of applica
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features three poles and is constructed with an F frame size. It offers an interrupt rating of 65 kA at 240 Volts AC and utilizes a thermal magnetic trip unit for both long-time overload and instantaneous short circuit protection. The device supports frequencies of 50/60 Hertz a
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker is categorized as a three-pole unit within the Series C lineup. It has interrupting ratings of 200 kAIC at 240 VAC and 100 kAIC at 480 VAC. The trip mechanism is fixed thermal and fixed magnetic, supporting long-time and instantaneous trip functions. The LDC3600F has a robust L-
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Capable of interrupting up to 65 kAIC at 240 Volts AC, the GHB3040 is equipped with a fixed thermal-magnetic trip mechanism for reliable operation. This circuit breaker is suitable for environments rated up to 40°C and uses aluminum for its terminal connections.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
The trip unit features three poles and includes long-time and instantaneous tripping functions (LI). With a frequency rating between 50 and 60 Hertz, this thermal magnetic trip unit is compliant with UL standards and is compatible with multiple circuit breaker frames, including CKD and KD.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This motor circuit protector features three poles and a magnetic trip range from 90 A to 300 A. It has an interrupting capacity of 65 kAIC at 480 VAC. This unit can function efficiently within a temperature range of -20°C to 70°C, with storage capabilities extending from -60°C to 90°C.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This model is equipped with three poles and utilizes a thermal magnetic tripping unit. It also supports overcurrent protection functionalities with long-time and instantaneous response capabilities. The FDB3050 has a maximum interrupt capacity of 14 kA at 480 V AC and 18 kA at 240 V AC, making it su
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Designed as a three-pole breaker within an F-frame type, the FDC3125 provides impressive interrupting capacities: 200 kAIC at 240 VAC, 100 kAIC at 480 VAC, and 35 kAIC at 600 VAC. It features fixed thermal and magnetic trip mechanisms, enhancing protective measures in circuit management.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Featuring a J frame type, the JD3250 circuit breaker supports an interrupting capacity of 65 kAIC at 240 VAC and 35 kAIC at 480 VAC. Its trip functions are configured for both long-time and instantaneous reactions, providing reliable protection. The terminal connections utilize standard pressure lug