507 results
Schneider Electric / PowerPact
This molded case circuit breaker operates continuously at an 80% rating, supporting various conductor sizes from 3 x AWG 3/0 to 500 kcmil for both aluminum and copper types. Its electronic trip unit facilitates accurate current regulation, while the adjustable overload range spans from 40% to 100% o
Schneider Electric / PowerPact
This device incorporates three poles and supports a magnetic hold current of 900 Amperes. It exhibits breaking capacities across varying voltages, specifically rated for 20 kA at 250 Volts DC and up to 125 kA at 240 Volts AC. The effective operational range extends from -25 to 70°C with storage opti
Schneider Electric / PowerPact
This circuit breaker features an operating handle for control and utilizes thermal-magnetic trip technology for effective current management. It supports continuous operation at 80% of its rated current. The device includes a rated impulse withstand voltage of 8 kV and operates within a frequency ra
Schneider Electric / PowerPact
This three-pole circuit breaker is rated for a line current of 50 Amperes and features a magnetic hold current of 400 Amperes. Its tripping mechanism combines thermal and magnetic technologies. The HJL36050 operates at a rated voltage of up to 250 Volts DC and 600 Volts AC, providing high breaking c
Schneider Electric / PowerPact
This circuit breaker handles operational voltages up to 690V AC as defined by IEC 60947-3. Interrupting capacity is notable, rated at 100 kA for 240V AC and 65 kA for 480V AC, making it suitable for demanding applications. It features a manual toggle switch for actuation and incorporates thermal and
Schneider Electric / PowerPact
This 3-pole circuit breaker features a breaking capacity of 20 kiloamperes at 250 Volts DC and supports significant loads, with breaking capacities of 100 kiloamperes at 240 Volts AC, 65 kiloamperes at 480 Volts AC, and 25 kiloamperes at 600 Volts AC. The HJA36060 includes thermal-magnetic trip unit
Schneider Electric / PowerPact
The FH36015 features a thermal magnetic trip unit and offers a breaking capacity code of H. It operates with a magnetic hold current of 275 A and a tripping current of 600 A, making it reliable for protective applications. The circuit breaker has an I Line mounting mode and connects using lugs, with
Schneider Electric / PowerPact
This circuit breaker features adjustable earth-leakage sensitivity, ranging from 30 mA to 3000 mA. Users can also modify the earth-leakage protection time delay from consecutive settings, including instantaneous to 500 ms. Local signalling indicates trip events, and a plug-in connection enhances use