Schneider Electric / PowerPact
This trip unit belongs to the PowerPact series and features a three-pole configuration within a J-Frame type assembly. The JT3200 operates at a frequency of 50/60 Hz and is rated for voltages up to 600 VAC. It complies with UL and CSA standards and is specifically designed for AC overcurrent applica
Schneider Electric / PowerPact
This circuit breaker features a breaking capacity of 25 kA and is classified under breaking capacity code D. It functions at frequencies ranging from a minimum of 50 Hz to a maximum of 60 Hz. The device has an impulse withstand voltage of 8 kV and employs a magnetic tripping current of 2400 A, with
Schneider Electric / PowerPact
This neutral current transformer has a compact physical design, measuring 8.11 inches in length, 2.96 inches in width, and 5.07 inches in height. It weighs 5.7 pounds and offers a torque requirement of 300.9 lbf·in for installation. The transformer includes four screw-type terminals and operates eff
Schneider Electric / PowerPact
This safety switch features a non-fusible disconnect and is capable of supporting motor power of 50 horsepower. It is mounted on surfaces and offers electrical connections through lugs, with a wiring configuration accommodating two wires. Designed with a NEMA 1 enclosure rating, it provides basic pr
Schneider Electric / PowerPact
Featuring a three-pole configuration, the PJL36000S80 has a breaking capacity of 25 kA. The device accepts electrical connections with sizes ranging from 3 x AWG 3/0 to 3 x 500 kcmil. The switch includes lugs for line and load connections and requires a tightening torque of 442.5 lbf.in (50 N.m). It
Schneider Electric / PowerPact
This circuit breaker operates at input voltages between 380 and 480 volts AC and can handle a frequency of either 50 or 60 Hz. It is designed for use in M, P, or R frame types and qualifies for UL approval, reinforcing its reliability as a safety component.
Schneider Electric / PowerPact
This circuit breaker operates at a rated voltage of 600 V AC and supports both 50 Hz and 60 Hz frequencies. The MicroLogic 6.0 A electronic trip unit ensures reliable protective functions while maintaining an 80% continuous current rating. The breaker features a rated impulse withstand voltage of 8
Schneider Electric / PowerPact
This device has a breaking capacity of 100 kA and operates at a rated voltage of 690 V with a network frequency of 50/60 Hz. The rated service breaking capacity is specified as 65 kA, and it withstands impulse voltage up to 8 kV. The protected system can trip magnetically between 84 A to 546 A, with
Schneider Electric / PowerPact
Designed for robust applications, this circuit breaker accommodates a busbar connection type. It has a continuous current rating of 80% and operates effectively up to 600 V AC. The unit supports an interrupting capacity of 18 kA at the same voltage while maintaining compliance with multiple certific
Schneider Electric / PowerPact
This circuit breaker offers a breaking capacity of 10 kA and a breaking capacity code of B. It is designed for a rated voltage of 240 V with operational frequencies between 50 Hz and 60 Hz. The thermal-magnetic trip technology allows for magnetic tripping at a threshold of 2400 A while maintaining a