466 results
Siemens / SENTRON
Equipped with two poles, the JXD22B400 circuit breaker operates under a thermal magnetic protection scheme, providing enhanced safety features. It has an interrupt rating of 65 kAIC at 240 Vac and supports both long-time and instantaneous trip functions. This breaker is designed for bolt-on mounting
Siemens / SENTRON
Feature-wise, this circuit breaker is engineered for three-phase applications and accommodates frequencies from 50 to 60 Hz. The connection is made via load lug terminals. It has a significant interrupt rating of 18 kA. The trip mechanism is thermal/magnetic, providing reliable protective measures t
Siemens / SENTRON
This circuit breaker has an interrupting capacity of 35 kA at 480 V and 18 kA at 600Y/347 V, effectively handling significant electrical faults. It features a 3-pole configuration and connects through lug or clamp methods. Built to withstand demanding conditions, it has an IP40 protection class and
Siemens / SENTRON
This circuit breaker is compliant with UL and IEC standards and is configured for a maximum interrupt rating of 65 kAIC at 240 Vac. It employs a thermal magnetic protection mechanism and supports long-time and instantaneous trip functions, enhancing safety and performance in electrical systems.
Siemens / SENTRON
This circuit breaker features two poles and a thermal magnetic trip unit, ensuring effective overload protection. It has an interrupting capacity of 65 kA at 240 Volts AC, 35 kA at 480 Volts AC, and 25 kA at 600 Volts AC. The trip range is adjustable between 2000 and 4000 Amperes, providing flexibil
Siemens / SENTRON
This device includes three poles and incorporates thermal magnetic protection for long-time and instantaneous trip functions. It is rated for operation at frequencies of 50/60 Hz and supports bolt-on connections. Approvals from organizations like UL and IEC enhance its reliability, while the enclosu
Siemens / SENTRON
This thermal magnetic trip unit offers three poles and incorporates various protection functions including long time, instantaneous, and short time trip settings. It has an interrupt rating of 25 kA at 600 Volts AC and 35 kA at 480 Volts AC, ensuring effective fault handling. Designed to operate wit
Siemens / SENTRON
This trip unit accommodates three poles and operates at a maximum rated voltage of 600 V AC. It employs thermal-magnetic technology for trip functions, providing both long-time and instantaneous protection settings. The connection method is bolt-on, and it is compatible with both copper and aluminum