Schneider Electric / PowerPact
This circuit breaker, part of the PowerPact series, measures 340 mm in height, 140 mm in width, and 110 mm in depth. It is constructed with an L-frame design and is categorized under Utilization Category A. The breaker integrates a MicroLogic 3.3 electronic trip unit and has an impulse-withstand vol
Schneider Electric / PowerPact
This circuit breaker is capable of functioning within an operating temperature range of -25°C to 55°C. It boasts a mechanical endurance of 10,000 operations and an electrical endurance of 20,000 operations. The S33662 model can be mounted on a DIN rail or directly onto a panel. It is housed in a dur
Schneider Electric / PowerPact
This circuit breaker features a robust design with three poles and a rated current capacity of 800 A. It employs a thermal magnetic mechanism (ET 1.0I) for reliable performance. The PGA36080 also has a rated insulation voltage of 750 V as per IEC 60947-2 standards, and it achieves a rated impulse vo
Schneider Electric / PowerPact
This three-pole device features a magnetic hold current of 900 amperes and offers multiple breaking capacities for different voltage levels. Designed for environments with ambient temperatures ranging from -25 to 70 °C, it also provides a storage temperature range of -50 to 85 °C. This circuit break
Schneider Electric / PowerPact
This device has a breaking capacity of 100 kA and operates at a rated voltage of 690 V with a network frequency of 50/60 Hz. The rated service breaking capacity is specified as 65 kA, and it withstands impulse voltage up to 8 kV. The protected system can trip magnetically between 84 A to 546 A, with
Schneider Electric / PowerPact
This circuit breaker features a breaking capacity of 25 kA and is classified under breaking capacity code D. It functions at frequencies ranging from a minimum of 50 Hz to a maximum of 60 Hz. The device has an impulse withstand voltage of 8 kV and employs a magnetic tripping current of 2400 A, with
Schneider Electric / PowerPact
This safety switch has two poles and utilizes a non-fusible disconnect type. It supports motor power of up to 50 horsepower and is designed for surface mounting. The wiring configuration is a simple two-wire setup, accommodating wire sizes ranging from AWG 3/0 to 750 kcmil for both copper and alumin
Schneider Electric / PowerPact
This circuit breaker boasts a breaking capacity code of J and can handle a line-rated current of 200 A. It supports a continuous current rating of 80%, with a magnetic hold current of 1200 A and a magnetic trip current of 2400 A. The dimensions of this device are 6.47 in high, 3.00 in wide, and 3.93
Schneider Electric / PowerPact
This circuit breaker is certified by UL, CSA, IEC, NEMA, and NOM. It utilizes thermal-magnetic trip unit technology capable of handling magnetic hold currents up to 1200 A, with a trip current rating of 2400 A. It is designed for unit mount installation and has dimensions of 6.47 inches in height, 4
Schneider Electric / PowerPact
This circuit breaker supports a network frequency of 50/60 Hz. It incorporates thermal magnetic trip unit technology, with magnetic tripping currents reaching 2400 A and a hold current of 1200 A. The unit's continuous current rating operates at 80%, and it mounts via unit mount lugs, allowing for st